Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0223-02966
Parcel: 121061290

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - TC-RES-0223-02966
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
03/10/2023 Site Engineering NOT REQUIRED
03/23/2023 Bldg Permits - Post Review Express PENDING ASSIGNMENT
03/20/2023 Residential Building REQUIRES RESUBMIT Permit Review TC-RES-0223-02966 (1313 N SAHUARA AV TUCSON, AZ 85712)

Site Plan Review:
1. Provide complete dimensions of all structures on site.

Floor Plan Review:
2. Label all rooms and spaces, including all rooms adjoining the addition. R106.1.1. Note: removing or enclosing windows from sleeping rooms may require new emergency escape rescue openings, R310.
3. Show location, size and operable portion of all doors and windows, R106.

Foundation Plan Review:
4. Provide location for all footings.
5. Provide a floor or landing outside exterior doors, R311.3.
6. All exterior framed walls require continuous concrete footings min. 12” wide x 12” below grade with treated sill plates and anchor bolts per R403.1 & R403.1.6.
7. Specify height above grade for finished floor.

Structural/Framing Plan Review:
8. Provide header schedule consistent with Table 602.7(1).
9. Provide a complete braced wall line layout showing the location of braced wall panels within 10’ of each end of each braced wall line and shall be no more than 20’ apart, R403.1.6, R602.10.2.2.

Sections – Details:
10. Specify height above grade for finished floor.
11. Detail footing width, height, and depth (min. 12” below grade into undisturbed soil.)
12. Stucco: Show weep screeds with a min. clearance of 4” above grade or 2” above paved areas, R7l,03.7.2.1.
13. Specify wall and ceiling coverings, Table R702.3.5.

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov
03/23/2023 Site Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Nathan Herrera
Planner

PROJECT: TC-RES-0223-02966
1313 N Sahuara Ave. Tucson, AZ. 85712
Enclosure of existing patio to livable space- 1st Review

TRANSMITTAL DATE: 3/23/23

This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 -.9.

1. Add in driveway of property to rear carport and add total square footage to lot coverage calculation.
2. Per UDC 4.9.7.B.7 provide floor plan of current residence to ensure that the property does not exceed 5 or more bedrooms. If the property does exceed 5 bedrooms, there must be at least 3 parking space provided. All parking spaces must be located on-site, either in a side or rear perimeter yard. Parking spaces may not be located in a vehicular use area in any front street perimeter yard. A parking area is not required to be developed to a commercial standard. A dustproof parking surface is required to at least a minimum of two inches of compacted pea gravel. An existing covered residential parking area may be used.


RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised residential building permit. To resubmit visit Tucson Development Center at https://tdc-online.tucsonaz.gov/#/home. Instructions for resubmittal - https://www.tucsonaz.gov/files/pdsd/website/Resubmittals.pdf.



If you have any questions about this transmittal, please contact Nathan Herrera at Nathan.Herrera@tucsonaz.gov .
03/01/2023 PDSD Application Completeness Express REVIEW COMPLETED