Review Date Reviewer's Name Type of Review Description Status Comments
04/03/2023 Bldg Permits - Post Review Express PENDING ASSIGNMENT
04/03/2023 Light Residential Building Review (OIP) REQUIRES RESUBMIT Permit Review TC-RES-0223-02873 (1228 E HEDRICK DR TUCSON, AZ 85719)
STRUCTURAL PLANS:

1. Provide a Roof Framing Plan showing the location and size of beams, rafters, rails, etc. for supporting dead structural loads, R804. Identify dead loads.
2. Identify all fasteners for wind loading compliance. Show roof (uplift resistance) fasteners with appropriate uplift capacity, R802.11 amended.
3. Show footing depth, size, and post attachment anchors.

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov
04/03/2023 Site Engineering REQUIRES RESUBMIT This project is within a regulated floodplain and requires a Floodplain Use Permit (FUP.)
Please start a new FUP at our permit application web page:
https://tdc-online.tucsonaz.gov/#/home
NOTE: Documentation of a cost estimate from your contractor will be required if this project involves any reconstruction, repair, rehabilitation, structurally connected addition, or other improvement of an existing structure (including TI’s and solar). Construction of separate builds/new structures does not require a cost estimate to be provided.
Instructions:
1. Navigate into the current project in the “My Work” tab. Within the permit, navigate to the “Sub-Records” tab and click “Apply” on the Floodplain Use Permit Sub-Record
2. Locations -> Confirm the location is accurate to the project. Click “Next”
3. Type -> Fill in the “Square Feet” and “Valuation” boxes with the project area and a contractor-provided cost estimate (See note above: for new structures, input 0). Click “Next”
4. Contacts -> Confirm contacts and add any additional contacts if applicable. Click “Next”
5. More Info -> This will be filled in by the engineer assigned to your case, Click “Next”
6. Attachments -> Please attach the project plan, supporting documentation for the cost estimate (if applicable), and a drainage/hydrology report (if applicable). Click “Next”
7. Signature -> Read the statement and type your name. Sign your name below (You may Enable Type Signature to have the software sign for you.) Click “Next”
8. Review and Submit -> Review all information to ensure accuracy. Click “Submit”
Contact Scott Haseman at scott.haseman@tucsonaz.gov or Stephen Blood at Stephen.Blood@tucsonaz.gov if you have any questions about the FUP.
04/03/2023 Site Zoning REQUIRES RESUBMIT FROM: PDSD Zoning Review

PROJECT: TC-RES-0223-02873
1228 E Hedrick Dr. – R-2
Shade Structure w/Solar (1st Review)

TRANSMITTAL DATE: April 03, 2023

Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This site is located in the R-2 zone (UDC 4.7.9). A single family residence is a permitted use in the zone, (Table 4.8-2), subject to Use Specific Standards 4.9.7.B.6, .9, & .10.

1. Provide a lot coverage calculation on the plot plan that meets the requirements of UDC Article 6.4.3 and the example shown on the Residential Plot Plan Requirements found at: https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf.

2. Perimeter yard setbacks are based on a measurement from design grade to the highest point of the exterior wall UDC Article 6.4.5.B & Figure 6.4.5-A. The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A). For shade type structures the measurement for determining perimeter yard setbacks is from design grade to the top of beam supporting the roof structure, UDC Article 6.4.5.B.2. Based on a wall height of 11’-11/2” the required perimeter yard setback from the proposed structure to the east property line is 7’-5”, proposed setback is 3’-3”. Based on a wall height of 8’-0” the required perimeter yard setback from the proposed structure to the south property line is 6’-0”, proposed setback is 4’-6”. Per UDC Article 6.6.2.D An accessory structure that exceeds the allowable height of a wall within a perimeter yard and is detached from a principal structure shall comply with the perimeter yard width standards of the principal structure, except that the accessory structure may be built to a parcel line with the consent of the adjoining or, when separated by an alley, adjacent property owner(s). To secure this neighbor setback waiver the following statement must be provided on the plot plan and be signed and dated by the adjacent property owner(s):
My Name is____________________ and I am the owner of the property located at_______________________. I have reviewed the site plan and I have no objection to structure being located or constructed________ feet from the property line as depicted on the site plan.

Signature: _____________________________

Date: _________________________________

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov
03/04/2023 PDSD Application Completeness Express REVIEW COMPLETED