Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0223-02836
Parcel: 116183780

Review Status: Requires Resubmit

Review Details: COMMERCIAL PDSD SIMPLE REVIEW v.1

Permit Number - TC-RES-0223-02836
Review Name: COMMERCIAL PDSD SIMPLE REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
02/15/2023 Bldg Permits - Post Review Express PENDING ASSIGNMENT
02/15/2023 Light Residential Building Review (OIP) REQUIRES RESUBMIT Permit review TC-RES-0223-02836

PLUMBING Plans:
1. Note and specify all piping materials, P2609.
2. Pipe sizes are too small. See https://www.tucsonaz.gov/files/pdsd/permits/GAS_HANDOUT_2018_IRC_2019.2.4.pdf
3. Use Table G2413.4(1) to calculate correct required sizes. Calculated Developed Length of 54’ and Total Demand of 364,000 BTU/H, from the documents provided. Convert BTU/H to Cubic feet of Gas per Hour by dividing BTU/H number by 10.
4. Line to Furnace/Tankless 299,000 BTU/H, 54’, 1 ¼” min.

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov
02/15/2023 PDSD Application Completeness Express REVIEW COMPLETED