Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL PDSD SIMPLE REVIEW v.1
Permit Number - TC-RES-0223-02836
Review Name: COMMERCIAL PDSD SIMPLE REVIEW v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/15/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 02/15/2023 | Light Residential Building Review (OIP) | REQUIRES RESUBMIT | Permit review TC-RES-0223-02836 PLUMBING Plans: 1. Note and specify all piping materials, P2609. 2. Pipe sizes are too small. See https://www.tucsonaz.gov/files/pdsd/permits/GAS_HANDOUT_2018_IRC_2019.2.4.pdf 3. Use Table G2413.4(1) to calculate correct required sizes. Calculated Developed Length of 54β and Total Demand of 364,000 BTU/H, from the documents provided. Convert BTU/H to Cubic feet of Gas per Hour by dividing BTU/H number by 10. 4. Line to Furnace/Tankless 299,000 BTU/H, 54β, 1 ΒΌβ min. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 02/15/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |