Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.3
Permit Number - TC-RES-0223-02725
Review Name: RESIDENTIAL NEW DWELLING v.3
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/10/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 04/09/2025 | Addressing Validation | REQUIRES RESUBMIT | The address on the plans does not match with the Permit Application address; please confirm the address. It seems that this project is intended for Unit 1. Main Address and Unit 1 must be assigned to the Permit Application and Plans before issuance. Please log into your TDC account and submit a Change of Address Request. In your next submittal you should also include Comment Response and Plans with the Main Address and Unit 1 on ALL plan sheets. | ||
| 04/21/2025 | Residential Building | REQUIRES RESUBMIT | TC-RES-0223-02725 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. GENERAL REQUIREMENTS: The City of Tucson adopted the 2018 IRC with amendments and building ordinances for all dwellings. Provide a response letter addressing each comment with location of change on the plans. Submit separate letter and plan set files. SECTIONS - DETAILS: 1. Show the required joist/rafter bearing contact to a wall or beam structure with foundation, R502.6 & R802.6. Replace the rafter connection to fascia or provide a registered Arizona engineer design analysis with sealed plan. Detail #3/A103. 2. Attic space requires a ventilation calculation for showing the attic vent opening size using 1 to 150 of attic area in compliance with R806.2. Detail #3/A104. PLUMBING PLANS: 1. Tucson Water Department limits flow rates for each water meter size in compliance with P2903.7. Show an appropriate water meter size. 2. Remove the exterior gray drain lines and basins. The gray water Ordinance #10579/11089 is intended for landscape discharge during occupancy after final inspection. MECHANICAL PLANS: 1. Provide (an HVAC system with fresh air intake) whole-house mechanical ventilation with controlled exhaust, R303.4; N1103.6 & M1505.4. Identify the device model number providing an adjustable setting and note the minimum continuous setting. A one-bedroom dwelling under 1501 SF requires a 30 CFM continuous setting. ELECTRICAL PLANS: 1. Clarify the location of circuit #16 & 22 on sheet E702, E3404.13 & E3706.2. INTERNATIONAL ENERGY CONSERVATION CODE: 1. Energy Certificate: (Mandatory) place near the indoor furnace or in utility room, N1101.14. Add notation to plans. Please contact the plans reviewer if you have any questions: Ken Van Karsen PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services |
||
| 05/10/2025 | Site Engineering - Standard | REQUIRES RESUBMIT | TC-RES-0223-02725 1028 N Contzen AV Site Engineering comments are as follows: 1. This project requires further review, as it is a part of a larger development and may require a Development Package. See permit numbers: TC-RES-0223-02530 TC-RES-0425-01746 TC-RES-0325-01669 TC-RES-0223-02734 TC-RES-0425-01772 TC-RES-0224-00591 TC-RES-0123-01844 Ryan Insalaco – ryan.insalaco@tucsonaz.gov |
||
| 04/24/2025 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: TC-RES-0223-02725 1028 N Contzen Ave - R-3 ADU Unit #1 (3rd Review) TRANSMITTAL: April 24, 2025 Provided a detail comment response letter with your submittal that clearly shows how you have addressed all comments with your next submittal. This site is located in the R-3 zone (UDC 4.7.10). A single-family residence (SFR) with an Accessory Dwelling Unit is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.6, 8, & 9 and 6.6.3. 1. Based on the description provided in the Energov permitting system, “ADU Unit #1” you are proposing an Accessory Dwelling Unit (ADU). Per UDC Table 4.8-2 a single-family residence (SFR) with an Accessory Dwelling Unit is a permitted use in this R-3 zone. Permit TC-RES-0425-01746 for the primary residence will need to be approved and issued prior to approval of this permit. 2. Per UDC Article 6.6.3.C detached accessory buildings, including accessory dwelling units, are not permitted in the buildable area extending the full width of the lot between the principal building and the front street lot line. A Board of Adjustment for Variance will need to be submitted and approved for the ADU to be located within the front yard. Zoning recommends that you change the permit description to a single family residence as the R-3 zoned parcel supports 2 single-family residence to eliminate the variance requirement. Board of Adjustment application/requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration. Contact for the Board of Adjustment is Mark Castro at Mark.Castro@tucsonaz.gov. The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 04/09/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |