Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TC-RES-0223-02538
Parcel: 121071100

Review Status: Requires Resubmit

Review Details: COMMERCIAL PDSD SIMPLE REVIEW v.2

Permit Number - TC-RES-0223-02538
Review Name: COMMERCIAL PDSD SIMPLE REVIEW v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
03/20/2023 Bldg Permits - Post Review PENDING ASSIGNMENT
03/20/2023 Light Residential Building Review (OIP) REQUIRES RESUBMIT Permit Review TC-RES-0223-02538 (5955 E LEE ST Unit:UNIT 1 TUCSON, AZ 85712)
All code references are to 2018 International Residential Code.
PLUMBING Plans:
1. Note and specify all piping materials and sizes, P2609.
a. Missing both piping materials and size.
2. The provided gas piping plan should show all connected appliances and distances.
3. Use G2413.4.1 and G2413.4.2 to determine the required developed length.
a. Developed length is from meter to farthest connected appliance.
4. To calculate correct required pipe size for new pipe, use the correct Table below
a. Use Table G2413.4(1) (metallic pipe)
b. Use Table G2413.4(7) (Polyethylene plastic pipe)

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov
03/18/2023 PDSD Application Completeness REVIEW COMPLETED