Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0223-02534
Parcel: 121121210

Review Status: Requires Resubmit

Review Details: COMMERCIAL PDSD SIMPLE REVIEW v.1

Permit Number - TC-RES-0223-02534
Review Name: COMMERCIAL PDSD SIMPLE REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
02/17/2023 Bldg Permits - Post Review Express PENDING ASSIGNMENT
02/17/2023 Light Residential Building Review (OIP) REQUIRES RESUBMIT PLUMBING Plans:
1. Note and specify all piping materials and sizes, P2609.
2. Use G2413.4.1 and G2413.4.2 to determine required developed length.
3. Use Table G2413.4(1) to calculate correct required pipe sizes.
4. Pipe size to RTU is undersized: using G2413.4.1, developed length = 36’, load = 99Kbtu -> Table G2413.4(1) ¾” required.

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov
02/06/2023 PDSD Application Completeness Express REVIEW COMPLETED