| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/10/2026 | Residential Building - Standard | APPROVED | |||
| 02/27/2026 | Residential Engineering | NOT REQUIRED | |||
| 03/12/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 03/12/2026 | Residential Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Jeffrey W. Cassidy, Planner Planning & Development Services Department – Current Zoning Review Section PROJECT: TC-RES-0126-00329 – Residential Building – Bedroom and Porch Addition to guest house 1938 N DODGE BL Unit 2 TUCSON, AZ 85716 (R-1 Zoning) Site Plan Review – 1st Review TRANSMITTAL DATE: March 12, 2026 This site is in the R-1 Residence Zone (UDC 4.7.8). A single-family residence is permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 - .9 for 1 unit; 4.9.7.B.1 - .9, & .11 for 2 units (min. 10,000 sq ft lot size required). The City's Unified Development Code (UDC) (Section 1.4.1.C) establishes that before the City issues any approvals or permits; we must confirm that a site complies with UDC standards. Therefore, as part of permit reviews, we review a site's permit history and compare it to aerial photography to confirm that unpermitted work has not occurred. In many cases, this does mean that a homeowner must apply for permits for unpermitted work before we can approve any new work on that site. Plan review for the above referenced bedroom and porch addition to the guest house has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued. 1. COMMENT: The site plan provided is incomplete. Specifically: A. Draw, label and dimension missing unpermitted shed to the rear of the property in between the two homes. Provide dimensions of shed, the height and dimensions to property lines. This shed can be added to this permitted. Acknowledge you would like to do in the comment response letter. B. The lot coverage calculation table is not correct. Recalculate property lines and adjust associated numbers in lot coverage table. Additionally, each residence minus the porch areas (and update lot coverage table). Per UDC Article 6.4.3.C.1.a roofed areas, porches, open on at least one side are NOT included in the calculation and per UDC Article 6.4.3.B.3.b Vehicular use areas, measured within the outside edges of any area allocated to vehicle use, whether improved or unimproved, are included in the lot coverage. 2. COMMENT: Additional comments may be forthcoming on the next review based on responses to Zoning and other PDSD reviewer comments. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: 1. Corrected building permit 2. Provide a detailed response letter (clarification narrative) with your submittal that clearly shows how you have addressed all Zoning comments. 3. Resubmit ALL documents associated with this permit (all drawings in sheet index) To resubmit visit Tucson Development Center at https://tdc-online.tucsonaz.gov/#/home Instructions for resubmittal - https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/old-pdfs/double-old/resubmittals.pdf If you have any questions about this transmittal, please contact jeffrey.cassidy@tucsonaz.gov The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code |
||
| 02/27/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |