Permit Number: TC-RES-0126-00320
Parcel: 115010070

Address:
619 E SENECA ST

Review Status: Requires Resubmit

Review Details: RESIDENTIAL ADD/ALT v.1

Permit Number - TC-RES-0126-00320
Review Name: RESIDENTIAL ADD/ALT v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
01/28/2026 Residential Engineering NOT REQUIRED
02/19/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
02/19/2026 Residential Building - Standard REQUIRES RESUBMIT Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide an updated complete plan set with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions\

If you have any questions about these Residential Building Safety comments, I can be reached at jorge.ruiz@tucsonaz.gov

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2024 International Residential Code and 2024 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet Zoning and other departmental requirements, conditions, and concerns before permit approval.



Provide a clear and concise construction plan set. Sample drawings are available for understanding details. Sample plans at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits

1. Provide complete drawings of all elevations, R301.1.

2. Indicate all materials used; stucco, concrete block, glass block, roofing system, siding, veneer, etc., R301.1.

3. Provide a wall section detail with reinforced foundations for anchoring exterior framed walls with pressure treated sills including ½” anchor bolts with 7” embedment, R403.1.6.

R703.7.2.1.

4. Clarify the placement of ceiling/roof insulation for determining the need for attic ventilation, R806. Attic space outside of the thermal barrier requires a ventilation calculation for showing the attic vent opening size using 1 to 150 of attic area in compliance with R806.2 or an unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing, R806.5. Show a roof design with insulation types and minimum thickness for meeting the condensation control requirement and the minimum total insulation value of R-38.

Please refer to https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/addition_sample.pdf for an example of plan drawings and elevations and pertinent information.
02/02/2026 Residential Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Claire Leighou, Planner

PROJECT: TC-RES-0126-00320

619 E SENECA ST

Convert existing garage to livable space, extend front wall (1st Review)

TRANSMITTAL DATE: 2/2/26

Please resubmit revised drawings with a detailed response letter stating how all Zoning Review Section comments were addressed.

This site is located in the R-2 zone (UDC 4.7.9). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6, .9, & .10.

Comment: Please add the following details to the site plan:

Property dimensions, which are 79’ by 87.5’ per subdivision plat map MP-07-006. Please note there is a 5’ easement along the north edge of the property that should be drawn and labeled.

Property owner information, zoning designation (R-2 Residential), and project description

Footprints and labels of all existing structures on the property, including dimensions and setback measurements

North arrow and engineer scale (i.e. 1”=10’)

The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code

If you have any questions about this transmittal, please contact Claire Leighou at claire.leighou@tucsonaz.gov. Thank you!
01/26/2026 PDSD Application Completeness Express REVIEW COMPLETED