Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL ADD/ALT v.1
Permit Number - TC-RES-0126-00299
Review Name: RESIDENTIAL ADD/ALT v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/04/2026 | Residential Zoning | APPROVED | |||
| 02/12/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 01/23/2026 | Addressing Validation | REQUIRES RESUBMIT | If you have questions regarding the Addressing Validation review comments, please contact PDSD-Residential@tucsonaz.gov When this initial review is over, please resubmit construction documents and include the property address (5823 E 18TH ST) on every page of the con docs. The full project address is required on every page. Step-by-Step instructions on how to resubmit: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf |
||
| 02/12/2026 | Residential Building - Standard | REQUIRES RESUBMIT | TC-RES-0126-00299 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2024 International Residential Code and 2018 International Energy Conservation Code. The 2024 International Energy Conservation Code takes effect July 1st. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2024 IRC code compliance. The plans require sufficient detail for demonstrating minimum building code compliance for passing all progress inspections. Place the 2024 IRC reference code on sheet A-1 rather than throughout the plans. Provide a separate response letter addressing each comment with location of change on the plans. SITE PLAN: 1. Show the location and size of buildings, utility meters and gas, water, electric and sewer or septic lines from property line to building, R106.1.1. Identify the utility lines requiring upgrade or replacement. 2. Identify the location and square footage of structural additions, R106.1.1. 3. Show the location of the electrical service panel, R106.1.1. An overhead service conductor may not pass over the proposed building without an 8-foot clearance above the roof, E3604.2.1. Check with TEP customer service for feasible service line options if passing over the roof. https://www.tep.com/electric-service-requirements. The service panel should be located at the proposed building close to the service transformer. PLANS: 1. Remove all outdated code references, R106.1.1. Incorrect entries were found on sheets A-1, P-1, E-1. SECTIONS - DETAILS: 1. Clarify the placement of ceiling/roof insulation for determining the need for attic ventilation, R806. Attic space outside of the thermal barrier requires a ventilation calculation for showing the attic vent opening size using 1 to 150 of attic area in compliance with R806.2 or an unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing, R806.5. Identify the ventilation requirements and insulation types for complying with the condensation control issues. MECHANICAL PLANS: 1. Show the proposed bedrooms HVAC systems size accordance with M1401.3, M1601.1. ELECTRICAL PLANS: 1. Specify high-efficacy luminaires with an efficacy not less than 45 lumens per watt or lamps with efficacy not less than 65 lumens per watt (LED devices), N1104.1. Update note #19. If you have any questions, please contact: Kenneth.VanKarsen@tucsonaz.gov City of Tucson Residential Building Safety |
||
| 01/23/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |