Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL ADD/ALT v.2
Permit Number - TC-RES-0126-00281
Review Name: RESIDENTIAL ADD/ALT v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/19/2026 | Residential Engineering | NOT REQUIRED | |||
| 03/10/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 03/10/2026 | Residential Building - Standard | REQUIRES RESUBMIT | TC-RES-0126-00281 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2024 International Residential Code and 2018 International Energy Conservation Code. The 2024 International Energy Conservation Code takes effect July 1st. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2024 IRC code compliance. The plans require sufficient detail for demonstrating minimum building code compliance for passing all progress inspections. Place the 2024 IRC reference code on the plans. Provide a separate response letter addressing each comment with location of change on the plans. Provide a clear and concise construction plan set. Sample drawings are available for understanding details. Sample plans at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Plan-Examples/Floor-Plan-Example SITE PLAN: 1. Show the location of the electric service panel, R106.1.1. 2. Identify the location and square footage of structural additions, R106.1.1. PLANS: 1. Show the functional name of the proposed room and each existing adjacent room, R106.1.1. Existing bedrooms with removed windows require code compliance for egress, R310. Include any alteration of door or window openings between existing and proposed rooms. SECTIONS - DETAILS: 1. Provide a wall section detail with material types identified, R403.1.6. MECHANICAL PLANS: 1. Show the HVAC system size accordance with M1401.3, M1601.1. PLUMBING PLANS: 1. Show any plumbing additions or alterations, R106.1.1. ELECTRICAL PLANS: 1. Designate the circuit number at the location of each light fixture, receptacle, appliance, and equipment disconnect switch, R106.1.1. 2. Show receptacle outlets at wall spaces 2’ or more with no wall point (exclude door openings) more than 6’ from a receptacle outlet, E3901.2. 3. Interior 15A & 20A circuits serving outlet locations (except garage, kitchen, and bathrooms) including receptacles, lights, and smoke detectors require combination type arc-fault circuit interrupters, E3902.16. Add notation to plans. 4. Show at least one wall switch controlled light or outlet in bathrooms, hallways, stairways, attached garages, outdoor entrances or exits and all habitable rooms, E3903.3. INTERNATIONAL ENERGY CONSERVATION CODE: 1. Show compliance with the energy code with type and rating of insulation, N1102.1. If you have any questions, please contact: Kenneth.VanKarsen@tucsonaz.gov City of Tucson Residential Building Safety |
||
| 02/26/2026 | Residential Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Georgia Pennington Planner PROJECT: TC-RES-0126-00281 8013 E TULIP TREE ST (Enclose Carport) (1st Review) TRANSMITTAL DATE: (2/26/26) This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 - .9. 1. Provide a complete plot plan that includes all the required elements. Use this link for guidance: https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/plan-samples/full-site-plan_feb2026.pdf 2. Provide a floor plan of the residence. 3. Additional comments may be forthcoming based on site plan. If you have any questions about this transmittal, please contact Georgia Pennington at Georgia.Pennington@tucsonaz.gov or at 520-837-6311. |
||
| 02/18/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |