Permit Number: TC-RES-0126-00256
Parcel: 136083300

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING REVISION v.3

Permit Number - TC-RES-0126-00256
Review Name: RESIDENTIAL NEW DWELLING REVISION v.3
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
04/15/2026 Residential Engineering NOT REQUIRED
04/22/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
04/21/2026 Residential Building Standard REQUIRES RESUBMIT Requires resubmit. If you have any questions, I can be reached at jorge.ruiz@tucsonaz.gov

Please note the following:

1. All code references need to be updated to the 2024 IRC. The City of Tucson adopted the code (along with amendments) at the beginning of 2026.

2. Dryer outlet needs to be GFCI.E3902.12 Appliance Outlets: GFCI protection is required for receptacle outlets or their branch circuit for: 

-Drinking water coolers 
-High pressure spray washing machines 
-Sump pumps 
-Dishwashers 
-Electric ranges 
-Wall-mounted ovens 
-Counter-mounted cooking units 
-Clothes dryers 
-Microwave ovens 

3. R506.3.3 Vapor retarder: a minimum 6 mil polyethylene vapor retarder with joints lapped not less than 6 inches is required between the concrete floor slab and the base course or the prepared subgrade where a base course does not exist.

 Exception: The vapor retarder is not required for the following:
-Garages, utility buildings and other unheated accessory structures.
-For unheated storage rooms having an area of less than 70 square feet (6.5 m2) and carports.
-Driveways, walks, patios and other flatwork not likely to be enclosed and heated at a later date.
-Where designed by a qualifying registered design professional, based on soil conditions and floor finishing such as exposed concrete surfaces.

4. Please provide calculations for roof vents.
04/22/2026 Residential Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Jeffrey W. Cassidy, Planner
Planning & Development Services Department – Current Zoning Review Section

PROJECT: TC-RES-0126-00256 – Residential Building – Closet, Patio & Carport Addition
2522 S BONANZA AV TUCSON, AZ 85748 (R-1 Zoning)
Site Plan Review – 2nd Review

TRANSMITTAL DATE: April 22, 2026

This site is in the R-1 Residence Zone (UDC 4.7.8). A single-family residence is permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 - .9 for 1 unit; 4.9.7.B.1 - .9, & .11 for 2 units (min. 10,000 sq ft lot size required).

The City's Unified Development Code (UDC) (Section 1.4.1.C) establishes that before the City issues any approvals or permits; we must confirm that a site complies with UDC standards. Therefore, as part of permit reviews, we review a site's permit history and compare it to aerial photography to confirm that unpermitted work has not occurred. In many cases, this does mean that a homeowner must apply for permits for unpermitted work before we can approve any new work on that site.

Plan review for the above referenced closet, patio & carport addition has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued.

1. COMMENT: After reviewing the property documentation history in Property Research Online (PRO), zoning could not verify any permit documentation for the existing shade sail just off the west face of the residence installed around 2023.

If you would like to keep the shade sail and get it permitted with this permit, draw, label and provide dimensions of the size of the shade sail and provide any information on how it is attached the residence.

2. COMMENT: Additional comments may be forthcoming on the next review based on responses to Zoning and other PDSD reviewer comments.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED:

1. Updated building permit.

To resubmit visit Tucson Development Center at https://tdc-online.tucsonaz.gov/#/home

Instructions for resubmittal - https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/old-pdfs/double-old/resubmittals.pdf

If you have any questions about this transmittal, please contact jeffrey.cassidy@tucsonaz.gov

The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code
04/15/2026 PDSD Application Completeness Express REVIEW COMPLETED