| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/14/2026 | Residential Building Standard | NOT REQUIRED | |||
| 04/30/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 04/24/2026 | Residential Engineering | REQUIRES RESUBMIT | Permit: TC-RES-1224-07272 Location: 6167 E DIABLO SUNRISE RD Review Date: 4/24/2026 A Comment Response letter is required. Please address all reviewer’s comments in a separate document with all required documents for resubmittal. Residential Engineering Comments: 1. Previous approval did not address visibility TSM 10-01.5.0. Before approval of revision, please resubmit plans with sight visibility triangles for the following locations: a. Hampton ST/1st AV, Near Side (looking south) 180 ft, Far Side (looking north) 110 ft b. Drive/1st AV, Near Side (looking south) 185 ft, Far Side (looking north) 110 ft c. Drive/Hampton ST, Near Side (looking east) 185 ft, Far Side (looking west) 110 ft d. No structure, wall or vegetation shall be located or maintained to interfere with the sight visibility triangles in accordance with Section 10-01.5.0 https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-12456 If you have any questions or concerns, please contact Dylan Molina. Dylan.Molina@tucsonaz.gov |
||
| 04/23/2026 | Residential Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Jeffrey W. Cassidy, Planner Planning & Development Services Department – Current Zoning Review Section PROJECT: TC-RES-0126-00244 –Residential Building – Several unpermitted structures property per CE-V1O0126-00017; 2125 N 1ST AV TUCSON, AZ 85719 (R-2 Zoning) Site Plan Review – 3rd Review, Revision re North Wall along E Hampton St TRANSMITTAL DATE: April 23, 2026 \This site is in the R-2 Residence Zone (UDC 4.7.9). A single-family residence is permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6, .9, & .10. The City's Unified Development Code (UDC) (Section 1.4.1.C) establishes that before the City issues any approvals or permits; we must confirm that a site complies with UDC standards. Therefore, as part of permit reviews, we review a site's permit history and compare it to aerial photography to confirm that unpermitted work has not occurred. In many cases, this does mean that a homeowner must apply for permits for unpermitted work before we can approve any new work on that site. Plan review for the above referenced several unpermitted structures has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued. 1. COMMENT: The site plan provided is incomplete. A. Per the construction documents for E Hampton St https://maps-and-records.tucsonaz.gov/construction-plans/details/I-510 sheet -004, provide THREE dimensions on the site plan: 1) North property (neighbor just north of this parcel) to customer property (this permit = Right of Way width of 50’-0”. 2) Centerline of E Hampton St to the front of curb (draw second curb line) (half of the 34’-0” paved street width shown) = 17’-0”. 3) Front of curb to north property line of this property = 8’-0”. 2. COMMENT: Additional comments may be forthcoming on the next review based on responses to Zoning and other PDSD reviewer comments. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: 1. Corrected building permit 2. Provide a detailed response letter with your submittal that clearly shows how you have addressed all Zoning comments. 3. Resubmit ALL documents associated with this permit To resubmit visit Tucson Development Center at https://tdc-online.tucsonaz.gov/#/home Instructions for resubmittal - https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/old-pdfs/double-old/resubmittals.pdf If you have any questions about this transmittal, please contact jeffrey.cassidy@tucsonaz.gov The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code |
||
| 04/30/2026 | ROW Engineering Review Standard | REQUIRES RESUBMIT | Provide construction note for reduction of wall height in the ROW to 30 inches | ||
| 04/10/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |