Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0126-00244
Parcel: 115010110

Address:
2125 N 1ST AV

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING REVISION v.2

Permit Number - TC-RES-0126-00244
Review Name: RESIDENTIAL NEW DWELLING REVISION v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
04/14/2026 Residential Building Standard NOT REQUIRED
04/30/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
04/24/2026 Residential Engineering REQUIRES RESUBMIT Permit: TC-RES-1224-07272
Location: 6167 E DIABLO SUNRISE RD
Review Date: 4/24/2026
A Comment Response letter is required. Please address all reviewer’s comments in a separate document with all required documents for resubmittal.

Residential Engineering Comments:
1. Previous approval did not address visibility TSM 10-01.5.0. Before approval of revision, please resubmit plans with sight visibility triangles for the following locations:
a. Hampton ST/1st AV, Near Side (looking south) 180 ft, Far Side (looking north) 110 ft
b. Drive/1st AV, Near Side (looking south) 185 ft, Far Side (looking north) 110 ft
c. Drive/Hampton ST, Near Side (looking east) 185 ft, Far Side (looking west) 110 ft
d. No structure, wall or vegetation shall be located or maintained to interfere with the sight visibility triangles in accordance with Section 10-01.5.0 https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-12456

If you have any questions or concerns, please contact Dylan Molina.
Dylan.Molina@tucsonaz.gov
04/23/2026 Residential Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Jeffrey W. Cassidy, Planner
Planning & Development Services Department – Current Zoning Review Section

PROJECT: TC-RES-0126-00244 –Residential Building – Several unpermitted structures property per CE-V1O0126-00017;
2125 N 1ST AV TUCSON, AZ 85719 (R-2 Zoning)
Site Plan Review – 3rd Review, Revision re North Wall along E Hampton St

TRANSMITTAL DATE: April 23, 2026

\This site is in the R-2 Residence Zone (UDC 4.7.9). A single-family residence is permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6, .9, & .10.

The City's Unified Development Code (UDC) (Section 1.4.1.C) establishes that before the City issues any approvals or permits; we must confirm that a site complies with UDC standards. Therefore, as part of permit reviews, we review a site's permit history and compare it to aerial photography to confirm that unpermitted work has not occurred. In many cases, this does mean that a homeowner must apply for permits for unpermitted work before we can approve any new work on that site.

Plan review for the above referenced several unpermitted structures has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued.

1. COMMENT: The site plan provided is incomplete.

A. Per the construction documents for E Hampton St https://maps-and-records.tucsonaz.gov/construction-plans/details/I-510 sheet -004, provide THREE dimensions on the site plan:

1) North property (neighbor just north of this parcel) to customer property (this permit = Right of Way width of 50’-0”.

2) Centerline of E Hampton St to the front of curb (draw second curb line) (half of the 34’-0” paved street width shown) = 17’-0”.

3) Front of curb to north property line of this property = 8’-0”.

2. COMMENT: Additional comments may be forthcoming on the next review based on responses to Zoning and other PDSD reviewer comments.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED:

1. Corrected building permit

2. Provide a detailed response letter with your submittal that clearly shows how you have addressed all Zoning comments.

3. Resubmit ALL documents associated with this permit

To resubmit visit Tucson Development Center at https://tdc-online.tucsonaz.gov/#/home

Instructions for resubmittal - https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/old-pdfs/double-old/resubmittals.pdf

If you have any questions about this transmittal, please contact jeffrey.cassidy@tucsonaz.gov

The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code
04/30/2026 ROW Engineering Review Standard REQUIRES RESUBMIT Provide construction note for reduction of wall height in the ROW to 30 inches
04/10/2026 PDSD Application Completeness Express REVIEW COMPLETED