Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0126-00188
Parcel: 140231350

Review Status: Requires Resubmit

Review Details: RESIDENTIAL ADD/ALT v.2

Permit Number - TC-RES-0126-00188
Review Name: RESIDENTIAL ADD/ALT v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
02/09/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
02/03/2026 Residential Building - Standard REQUIRES RESUBMIT Please ensure the shed and greenhouse maintain at least 3 feet from the property lines to ensure fire separation distance, Section R302.1 Exterior walls.
02/09/2026 Residential Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Claire Leighou, Planner

PROJECT: TC-RES-0126-00188

6022 S SOUTHLAND BL

Detached shed and greenhouse (1st Review)

TRANSMITTAL DATE: 2/9/26

Please resubmit revised drawings with a detailed response letter stating how all Zoning Review Section comments were addressed.

This site is located in the R-2 zone (UDC 4.7.9). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6, .9, & .10.

Comment 1: Based on the provided site plan, the proposed shed is located 1’ from the north property line. The minimum required setback for side and rear yards on residential lots is now 5’, per Middle Housing Ordinance HB2721. Per UDC Article 6.6.2.D, an accessory structure that is detached from a principal structure shall comply with the setback standards of the principal structure, except that the accessory structure may be built to a parcel line with the consent of the adjacent property owner(s). To secure this neighbor setback waiver the following statement must be provided on the plot plan and be signed and dated by the adjacent property owner(s) (6016 S Southland Blvd).

My name is____________________ and I am the owner of the property located at_______________________. I have reviewed the site plan and I have no objection to structure being located or constructed________ feet from the property line as depicted on the site plan.

Signature: _______________________Date: ___________________________

Comment 2: Please ensure the site plan is drawn to scale. Include an engineering scale (such as 1”=10’) on the next submitted site plan. Include property owner information and a brief description of the proposed project (detached shed and greenhouse).

Comment 3: Please draw, dimension, and label a setback measurement between the proposed greenhouse and the west property line. If that distance is less than the required 5’, a neighbor waiver will be needed to allow a reduced setback, as outlined in comment 1.

Comment 4: Please include lot coverage calculations on the site plan upon next submittal. Include the square footage of the existing residence, carport, vehicular use area (parking/driveway space), proposed structures, any other existing structures, and total lot coverage percentage. Porches do not need to be included in these calculations.



The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code

If you have any questions about this transmittal, please contact Claire Leighou at claire.leighou@tucsonaz.gov. Thank you!
02/02/2026 PDSD Application Completeness Express REVIEW COMPLETED