| 02/03/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 02/03/2026 | Residential Building - Standard | REQUIRES RESUBMIT | ACTIVITY NO. TC-RES-0126-00108 ADDRESS/PARCEL: (36 S GRANDE AV Unit:UNIT 1) Should you have any questions about these comments, I can be reached at Zane.Aouane@tucsonaz.gov Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. Review will not proceed without the response letter. COMMENTS: 1. R310.3 Location. Smoke alarms shall be installed in the following locations: In each sleeping room. Outside each separate sleeping area in the immediate vicinity of the bedrooms. 2. Provide Panel Schedule & load calculation for each service and provide a single line diagram indicating all services/sub panels type and size of feeders and conduits and grounding 3. FOUNDATIONS SUPPORTING WOOD SHALL EXTEND AT LEAST 6 INCHES ABOVE THE ADJACENT FINISH GRADE. 4. Provide plumbing plans if any lines are being moved or worked on. |
||
| 02/03/2026 | Residential Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Erick Bieber Planning & Development Services Department – Zoning Review Section PROJECT: TC-RES-0126-00108 36 S Grande Ave UNIT 1, Tucson, AZ 85745 Residential Addition/Alteration (1st Review) TRANSMITTAL DATE: February 3rd, 2026 This site is located in the R-2 zone (UDC 4.7.9). A single-family residence is a permitted use in this zone subject to use-specific standards 4.9.7.B.6, .9 and .10. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed. 1. (Comment) Aerial imagery indicates an unpermitted structure located on the existing concrete slab indicated by keynote 6. Please indicate the structure on the site plan or show that it has been removed. 2. (Comment) Please change “sleeping quarters” to “dwelling unit” on the plans. The structure appears to have a full kitchen as well as a separate address, making it its own dwelling unit, which is beyond the scope of a “sleeping quarters”. The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code For questions regarding Zoning comments, please contact me at: Erick.Bieber@tucsonaz.gov |
||
| 01/22/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |