Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL ADD/ALT v.3
Permit Number - TC-RES-0126-00075
Review Name: RESIDENTIAL ADD/ALT v.3
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/12/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 08/12/2026 | Residential Building - Standard | REQUIRES RESUBMIT | Please review the comments below and re submit. 1. Please provide a detail of the footers. Provide a wall section detail with (#4 rebar) reinforced 12” x 12” reinforced foundations for anchoring exterior framed (insulated) walls with pressure treated sills including ½” anchor bolts with 7” embedment, R403.1.6. 2. Clarify where the porch is attaching to the structure, can not be attached to the facia for structural support. 3. Provide a Roof Framing Plan with dimensions showing the beams sized for supporting live and dead structural loads (Table R602.7(3)) Top down view. |
||
| 08/12/2026 | Residential Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Roxanne Johnston, Planner PROJECT: TC-RES-0126-00075 3452 E Linden St., Tucson, AZ 85716 Porch Addition (2nd Review) TRANSMITTAL DATE: 08/12/2026 This site is located within the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 - .9. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed. 1. Either submit an application for either a Design Development Option if the project encroaches more than 1’ into the 5’ required side street setback, OR Submit an application for a Board of Adjustment variance if the structure lies within 1’ or less into the required 5’ side setback. The site plan does not show a dimension from the east side of the structure to the east property line. Per Unified Development Code (UDC) Table 6.3-2.A5. the required east side setback is 5. To submit an application for a Board of Adjustment Variance requesting a variance from the required 10’ side setback please visit www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration#section-2 and select the Board of Adjustment Variance application tab. To submit an application for a DDO, please use the following link and follow the instructions: www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/planning-amp-zoning/ddo-for-setback-and-height.pdf Submit a DDO application under the Zoning Modification sub-record that you will create. For instructions on how to apply for a sub-record, visit the following link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/new-pdfs/sub-records_071425.pdf For questions regarding the DDO process, please contact Georgia Pennington at georgia.pennington@tucsonaz.gov .The DDO process takes about 6 weeks from the time that the DDO application is accepted. Do not resubmit for this building permit TC-RES-0126-00075 until either a DDO or the Variance has been approved. 2. Once a decision has been approved by either the Board of Adjustment or the Design Development Option process (see Comment 1, above), please submit the following: a. Letter of Approval b. Revised site plan. The site plan lacks information required for approval. Please visit the following link which provides requirements and an example of a site plan. Choose the “Full site plan. https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Plan-Examples/Site-Plan-Examples The site plan submitted appears to have been partially copied from the site plan approved for the ADU (TC-RES-0225-01077). Much of the required information is on that site plan, so since the current proposal is for an open porch, the lot coverage will should not change. If re-using the site plan for TC-RES-0225-01077, please make sure there are no City stamps on the plan. c. Submit dimensioned elevations for the proposed structure with the construction plans from the north, south and west viewpoints. Lined draft paper is not accepted. d. A response letter explaining how all staff comments have been addressed. 3. Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted for the next review. The City of Tucson Unified Development Code may be accessed here: www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code If you have any questions about this transmittal, please contact Roxanne Johnston at roxanne.johnston@tucsonaz.gov |
||
| 08/12/2026 | Addressing Validation | REVIEW COMPLETED | |||
| 08/12/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |