Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.3
Permit Number - TC-RES-0125-00593
Review Name: RESIDENTIAL NEW DWELLING v.3
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/28/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 05/02/2025 | Addressing Validation | REQUIRES RESUBMIT | The address location does not have the 2nd unit attached to the address. Unit # will have to be confirmed and assigned to Permit Application and on Plans prior to issuance. Once Zoning approves the 2nd unit contact Pima County Addressing to resolve issue Addressing@pima.gov or 520-724-9512. Please submit a comment letter and Plans (with address and unit #). | ||
| 05/19/2025 | Residential Building - Standard | REQUIRES RESUBMIT | TC-RES-0125-00593 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. GENERAL REQUIREMENTS: The City of Tucson adopted the 2018 IRC with amendments and building ordinances for all dwellings. Show the current code reference on the plans. Provide a complete construction plan set with all sheets placed into a single PDF file, R106.1. Place a page number on each sheet. Each dwelling unit with kitchen requires a separate Pima County assigned street address after Zoning approval, R319. Show Pima County assigned unit numbers at each dwelling on the site plan. https://www.pima.gov/1010/Addressing-Frequently-Asked-Questions An impact fee payment is required for an ADU or second dwelling at the time of permit payment. Provide a response letter addressing each comment with location of change on the plans. Submit separate letter and plan set files. GENERAL COMMENTS : 1. Show compliance with the Inclusive Home Design Ordinance adopted by the City of Tucson Ordinance #10463 on 10/16/2007. Notate accessible route, minimum door width, changes in floor elevation, door hardware, electrical outlet reach range, grab bar reinforcement, etc. SITE PLAN: 1. Provide a single site plan showing all utility lines, R106.1.1. 2. Show the location, height and depth of any proposed retaining wall, R106.1.1. 3. Each dwelling unit should have an individual 3-foot clear space (including the roof projections) known as the fire separation distance for reducing fire spread to nearby buildings. Portions of buildings placed in a fire separation distance require one-hour fire-resistive construction in compliance with IBC Table 721.1(2). PLANS: 1. Notate a cool (white) roof finish (greater than 60 SRI) as required by the ADU provisions. See web site for ADU requirements https://casitas-in-tucson-cotgis.hub.arcgis.com/pages/new-casita 2. Show a maximum ½” floor elevation changes at a notated accessible route entrance on the floor plan, R106.1.1. 3. Provide a complete foundation plan including the interior foundation requirements, R301.1. SECTIONS - DETAILS: 1. Include the interior wall section detail in the plan set, R403.1. 2. An unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing, R806.5. Show a roof design with insulation types and minimum thickness for meeting the condensation control requirement and the minimum total insulation value of R-38. PLUMBING PLANS: 1. The Tucson Water Department limits flow rates for the water meter size in compliance with P2903.7. Show an appropriate yard pipe and water meter size for the additional demand. 2. Show an individual accessible water supply shut off and water heater for the proposed dwelling unit, P2903.9.1. 3. Show the water heater rating, P2801.1. MECHANICAL PLANS: 1. Provide demand calculations in accordance with Manual J standards, M1401.3, M1601.1. 2. Show the HVAC system size for the building demand in accordance with M1401.3, M1601.1. 3. Provide (an HVAC system with fresh air intake) whole-house mechanical ventilation with controlled exhaust, R303.4; N1103.6 & M1505.4. Identify the device model number providing an adjustable setting and note the minimum continuous setting. A one-bedroom dwelling under 1501 SF requires a 30 CFM continuous setting. ELECTRICAL PLANS: 1. Provide a Riser Diagram showing a service disconnect for both the primary and ADU dwelling, E3403. Show the ADU feeder size and appropriate breaker requirement, E3602.1 & E3603.1. 2. Provide a minimum service conductor rating of #3 copper 75 degree C for the 100 AMP feeder, E3602.1 & E3603.1. 3. Smoke alarms are required outside each separate sleeping area, R314.3.2. 4. Provide a panel schedule showing panel size, circuit numbers, ampacity, wire size and general description, E3404.13 & E3706.2. 5. Show two or more 2O AMP small appliance circuits at the kitchen countertop receptacle outlets; they may also serve the breakfast room and dining room, but not other locations, E3703.2 and E3901.3. 6. Show Bathroom receptacles with a separate 20 AMP dedicated circuit, E3703.4 and E3901.6. 7. Provide an exterior outlet at grade level located at both the front and back of the dwelling, E3901.7. 8. Interior 15A & 20A circuits serving outlet locations (except garage, kitchen, and bathrooms) including receptacles, lights, and smoke detectors require combination type arc-fault circuit interrupters, E3902.16. Add notation to plans. OUTDOOR LIGHTING CODE 1. Show full cutoff fixtures were located within 25 feet from the property line OLC 401.3.3. INTERNATIONAL ENERGY CONSERVATION CODE: 1. Energy Certificate: (Mandatory) place near the indoor furnace or in utility room, N1101.14. Add notation to plans. If you have any questions, please contact: Ken Van Karsen PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/pdsd |
||
| 04/29/2025 | Site Engineering - Standard | REQUIRES RESUBMIT | TC-RES-0125-00593 8822 E COLETTE ST Please provide updated site plans addressing comments provided in email correspondence. Chris Arrington chris.arrington@tucsonaz.gov |
||
| 05/28/2025 | Site Zoning - Standard | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-RES-0125-00593 8822 E COLETTE ST. – R-1 ADU Guest House & retaining wall (2nd Review) TRANSMITTAL DATE: May 28, 2025 COMMENTS: Resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 – 9. The following comments were not addressed. Address all comments and provide a detailed response letter with your next submittal that clearly shows how you have addressed all Zoning comments. 1. Provide a residential plot plan that meets the requirements found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Plan-Examples/Plot-Plan-Example, to include but not limited to: a. This comment was not addressed. The plot plan shall be drawn at an engineering scale, i.e. 1” = 10’, 1”=20’. b. Provide the property dimensions on the plot plan. c. Provide a lot coverage calculation on the plot plan. d. Provide the owners name on the plot plan. e. Label the zoning of this parcel and all adjacent parcels. f. Provide the legal description, “EASTERN HILLS LOT 11 BLK 5”, on the plot plan. g. Provide a dimension from the center line of both streets to the face of curb, where pavement meets the concrete curb, and from face of curb to the property line. Per Construction Plan I-62-027, sheets 6 & 8, found at: https://maps-and-records.tucsonaz.gov/construction-plans/details/I-62-027, the distance from centerline of Colette to face of curb is 16’ and from face of curb to the north property line is 9’ and the distance from centerline of Bedford to face of curb is 16’ and from face of curb to the north property line is 14’. h. Provide the height of the proposed ADU 2. Per UDC Article 6.4.5.C.1.b where a lot abuts more than one street, the owner chooses which street lot line is the front lot line. From other than the front lot line, the street perimeter yard is ten feet, as measured from the street property line, proposed side street perimeter yard setback is 6’-0”. A Design Development Option (DDO) to reduce the setback will need to be submitted and approved. DDO application and requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration. If you have questions about the DDO application or process, please contact Georgia Pennington at Georgia.Pennington@tucsonaz.gov”. 3. The description mentions “retaining wall” clearly show the retaining wall on the plan. 4. The drawings shall be submitted as a single multipage pdf file. The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 04/25/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |