Permit Number: TC-RES-0125-00562
Parcel: 115171010

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - TC-RES-0125-00562
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
03/20/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
02/07/2025 Addressing Validation REQUIRES RESUBMIT Please provide the complete address of proposed work on all submitted documents.

Step-by-Step instructions on how to resubmit: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf

For questions: building_official@tucsonaz.gov
02/26/2025 Residential Building - Standard REQUIRES RESUBMIT TC-RES-0125-00562
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance. The plans require sufficient detail for demonstrating minimum building code compliance for passing all progress inspections.

Note the 2018 IRC reference on the plans.

Provide a response letter addressing each comment with location of change on the plans. Submit separate letter and plan set files.

PLANS:

1. The roof structure may not extend to a point closer than 3 feet from the neighboring property line without fire rated protection for fire spread. Provide compliance with R302.1 (City of Tucson Amended) by protecting the structure placed within 3 feet of the property line in compliance with IBC Table 721.1(2). Include a one hour rated wall below the roof edge with foundation along the full length of structure near the property line or relocate the structure from the fire separation distance.
2. Also, a roof projection (overhang beyond beam) may not extend closer than 24” to the adjoining (neighboring) property line. Any part of a roof projection extending into the 3-foot fire separation distance from the property line requires not less than one-hour fire-resistive construction on the underside, R302.1 (City of Tucson Amended).


If you have any questions, please contact:
PDSD-Residential@tucsonaz.gov
City of Tucson Residential Plan Review

Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services
03/20/2025 Site Engineering - Standard REQUIRES RESUBMIT TC-RES-0125-00562
1870 N HUACHUCA AV

Site engineering comments are as follows:
1. Please see the comments of the other reviewers regarding the resubmittal requirements.
2. This project is within a FEMA regulated floodplain, El Rio Wash, and requires a Floodplain Use Permit (FUP).

Please start a new FUP at our permit application web page:
https://tdc-online.tucsonaz.gov/#/home

NOTE: A cost estimate of materials and labor from your contractor in the form of a pdf attachment will be required to complete the FUP application. Please have separate lines for cost of materials, and cost of labor. Thank you.

Ryan Insalaco – ryan.insalaco@tucsonaz.gov
03/10/2025 Site Zoning - Standard REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Krista Hansen
Planning & Development Services Department – Zoning Review Section

PROJECT: TC-RES-0125-00562
1870 N HUACHUCA AV TUCSON, AZ 85745
Residential Addition/Alteration (1st Review)

TRANSMITTAL DATE: 03/10/2025


This site is located in the R-2 zone (UDC 4.7.9). A single-family residence is a permitted use in this zone subject to use-specific standards 4.9.7.B.6, .9 and .10.


RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised plans, as noted in the comments below, along with a detailed letter indicating responses to the review comments.


1. COMMENT: Provide setback information on the two proposed porches and the storage shed in the northeast corner of the property.

2. COMMENT: Per UDC Table 6.3-2.A, the minimum side and rear yard setback for an attached structure (porch) is 6’-0” or 2/3 the height of the exterior wall, whichever is greater. Setbacks can be reduced to a minimum of 1’ from the property line with an approved Design Development Option (DDO) submittal. More information about the DDO can be found at: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/planning-amp-zoning/ddo_for_setback_and_height_udc.pdf. Please contact Georgia Pennington at georgia.pennington@tucsonaz.gov and/or Mark Castro at mark.castro@tucsonaz.gov upon completion of the application.

If the porches are less than 1’ from the property line, a Board of Adjustment Variance would be required.

3. COMMENT: The shed in the northeast corner of the property appears to not meet setbacks along the eastern property line, which is 6’-0” or 2/3 the height of the exterior wall, whichever is greater. To keep the shed in the existing location, a neighbor waiver must be obtained. "Per UDC Article 6.6.2.D, a detached accessory structure may be built to a parcel line with the consent of the adjoining or, when separated by an alley, adjacent property owner(s). To secure this neighbor setback waiver the following statement must be provided on the plot plan and be signed and dated by the adjacent property owner(s):

My Name is____________________ and I am the owner of the property located at_______________________. I have reviewed the site plan and I have no objection to structure being located or constructed________ feet from the property line as depicted on the site plan.

Signature: _____________________________

Date: _________________________________


4. COMMENT: Total lot coverage includes all Vehicular Use Area, which is defined in the UDC as, “Any area of a site or structure used for the movement, parking, or standing of motor vehicles.” Please confirm that lot coverage is accurate.


For questions regarding Zoning comments, please contact me at: Krista.Hansen2@tucsonaz.gov
02/07/2025 PDSD Application Completeness Express REVIEW COMPLETED