Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TC-RES-0125-00479
Parcel: 125151260

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - TC-RES-0125-00479
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
03/03/2025 Site Zoning - Standard APPROVED
03/04/2025 Site Engineering - Standard NOT REQUIRED
03/04/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
02/13/2025 Residential Building - Standard REQUIRES RESUBMIT TC-RES-0125-00479
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Facilitate a shorter back check time: provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance.

Provide a response letter on separate file with submitting the updated construction plan set.

PLANS:

1. Indicate the direction of slope for the garage slab, R309.1.
2. Identify the room usage with an opening into the proposed garage. Openings from a garage directly into a sleeping room are not permitted, R302.5.1.

SECTIONS - DETAILS:

1 The floor requires a slope for water runoff, R309.1, therefore the framed wall requires a concrete stem for achieving the 6” clearance between framing and ground (R317.1 item 5).
2 An unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing, R806.5. Show a roof design with insulation types and minimum thickness for meeting the condensation control requirement and the minimum total insulation value of R-38 or R-30 when extended over the wall top plate for additions under 500 SF.
3 Show garage opening narrow panels with fastening details using a prescriptive method at Figure R602.10.6.2, R602.10.6.3 or R602.10.6.4.
4 Identify all fasteners for wind loading compliance. Show roof (uplift resistance) fasteners (H2.5) with appropriate uplift capacity, R802.11 amended.

ELECTRICAL PLANS:

1. Show a smoke alarm both in the bedroom and outside the doorway in the immediate vicinity, R314.2.

If you have any questions, please contact:
PDSD-Residential@tucsonaz.gov
City of Tucson Residential Plan Review
01/31/2025 PDSD Application Completeness Express REVIEW COMPLETED