| 01/27/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 01/27/2025 | Light Residential Building Review (OIP) Express | REQUIRES RESUBMIT | Permit Review TC-RES-0125-00474 (2860 N WALNUT AV TUCSON, AZ 85712) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Residential Code (IRC). 1. The ¾” pipe going to the 200K BTU demand is undersized for the given length and appliance demand. A minimum 1" pipe is required. See drawing for markups. 2. The gas line is missing the meter location. Please show the connection to the meter. |
||