Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0125-00474
Parcel: 110062030

Address:
2860 N WALNUT AV

Review Status: Requires Resubmit

Review Details: RESIDENTIAL SIMPLE REVIEW v.2

Permit Number - TC-RES-0125-00474
Review Name: RESIDENTIAL SIMPLE REVIEW v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
01/27/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
01/27/2025 Light Residential Building Review (OIP) Express REQUIRES RESUBMIT Permit Review TC-RES-0125-00474 (2860 N WALNUT AV TUCSON, AZ 85712)

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Residential Code (IRC).

1. The ¾” pipe going to the 200K BTU demand is undersized for the given length and appliance demand. A minimum 1" pipe is required. See drawing for markups.
2. The gas line is missing the meter location. Please show the connection to the meter.
01/27/2025 PDSD Application Completeness Express REVIEW COMPLETED