Permit Number: TC-RES-0125-00457
Parcel: 11450011B

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - TC-RES-0125-00457
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
02/27/2025 Site Zoning - Standard APPROVED
03/04/2025 Site Engineering - Standard NOT REQUIRED
03/04/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
02/05/2025 Residential Building - Standard REQUIRES RESUBMIT TC-RES-0125-00457
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance.

Provide a response letter addressing each comment with location of change on the plans. Submit separate letter and plan set files.

SITE PLAN:

1. Show the permit number for the barn/shed alteration, R106.1.1.

PLANS:

1. Provide manufacturer’s calculations and data for engineered trusses sealed by a registered in Arizona engineer, or notate the requirement for deferred submittal, R106.1.

SECTIONS - DETAILS:

1. Show post-beam hardware at detail #1 on sheet S001.
2. Show rafter hangers at detail #2 on sheet S001.
3. Change second detail #5 to #6 on sheet S001.
4. Attic space outside of the thermal barrier requires a ventilation calculation for showing the attic vent opening size using 1 to 150 of attic area in compliance with R806.2 or venting of 1 to 300 of attic area if ridge vents are also included.

If you have any questions, please contact:
PDSD-Residential@tucsonaz.gov
City of Tucson Residential Plan Review

Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services
----------------------
01/31/2025 PDSD Application Completeness Express REVIEW COMPLETED