Permit Number: TC-RES-0125-00420
Parcel: 134050180

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - TC-RES-0125-00420
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
03/04/2025 Site Engineering - Standard NOT REQUIRED
03/04/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
02/06/2025 Residential Building - Standard REQUIRES RESUBMIT TC-RES-0125-00420
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance.

Provide a response letter addressing each comment with location of change on the plans. Submit separate letter and plan set files.

SITE PLAN:

1. Show the location of gas, water, electric and sewer lines from property line to building, R106.1.1. Identify the utility lines requiring upgrade or replacement.

SECTIONS - DETAILS:

1. Attic space outside of the thermal barrier requires a ventilation calculation for showing the attic vent opening size using 1 to 150 of attic area in compliance with R806.2.

PLUMBING PLANS:

1. The Tucson Water Department limits flow rates for the water meter size in compliance with P2903.7. Show an appropriate yard pipe and water meter size.
2. Show the proposed gas pipe segment sized in conformance with Table G2413.4(1). Existing gas pipes may require upgrading with this system alteration if the proposed segment is not extended to the gas meter.

ELECTRICAL PLANS:

1. Show a smoke alarm in the bedroom and outside the doorway in the immediate vicinity with an electrical circuit, R314.3.
2. Show a branch circuit for the sewage pump, E3702.5.
3. Show a wall-switch-controlled lighting outlet providing illumination on the exterior side of each egress door (SGD D3) having grade level access R3903.3.

OUTDOOR LIGHTING CODE

1. Show the proposed fixture as full cut-off FCO style or provide an Outdoor Lighting Calculation including all exterior fixtures on the property for determining exterior lighting limits. Show full cutoff fixtures were located within 25 feet from the property line OLC 401.3.3.

If you have any questions, please contact:
PDSD-Residential@tucsonaz.gov
City of Tucson Residential Plan Review

Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services
----------------------
02/27/2025 Site Zoning - Standard REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Krista Hansen
Planning & Development Services Department – Zoning Review Section

PROJECT: TC-RES-0125-00420
753 S SANTA ANA DR TUCSON, AZ 85710 – R-1
Residential Addition – Bedroom Suite (1st Review)

TRANSMITTAL DATE: 2/27/25


This site is located in the R-1 zone (UDC 4.7.8).

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised plans, as noted in the comments below, along with a detailed letter indicating responses to the review comments.

1. COMMENT: Label the adjacent zones on the site plan. Zones to the north and south are R-1, and the east is O-3.

2. COMMENT: Correct Setbacks note in Code Review section. Setbacks for the eastern property line is 10’ or ¾ the height of the adjacent wall, whichever is greater. The setback of the front perimeter yard is 20’. The maximum height allowed in the R-1 zone is 25’.

3. COMMENT: Draw, dimension, and label the vehicular use area.

4. COMMENT: Draw, dimension, and label the street centerline, half right-of-way, and sidewalk.

5. COMMENT: The front perimeter yard setback should mimic the property line. Revise.

6. COMMENT: Dimension the existing structure setbacks from all property lines.

7. COMMENT: Add building setbacks for the proposed addition, per UCD Section 6.4.5.B.5.

For questions regarding Zoning comments, please contact me at: Krista.Hansen2@tucsonaz.gov
01/30/2025 PDSD Application Completeness Express REVIEW COMPLETED