Permit Number: TC-RES-0125-00301
Parcel: 116180800

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.2

Permit Number - TC-RES-0125-00301
Review Name: RESIDENTIAL NEW DWELLING v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
03/13/2025 Site Engineering - Standard NOT REQUIRED
03/13/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
03/10/2025 Residential Building - Standard REQUIRES RESUBMIT TC-RES-0125-00301
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Facilitate a shorter back check time: provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance with component sizes. Show this code reference on the plans.

Place sheet numbers on each page.

Provide a response letter on separate file with submitting the updated construction plan set.

Provide a clear and concise construction plan set. Sample drawings for Garage are available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits

SITE PLAN:

1. Indicate the location of the electrical service panel, R106.1.1.
2. The structure may not extend to a point closer than 3 feet from the neighboring property line without fire rated protection for fire spread. Provide compliance with R302.1 (City of Tucson Amended) by removing the building placed within 3 feet of the property line or provide a complete wall barrier with not less than one-hour fire-resistive construction in compliance with IBC Table 721.1(2).
3. A roof projection may not extend closer than 24” to the adjoining (neighboring) property line, R302.1 (City of Tucson Amended). Remove the roof overhang along the property line.

PLANS:

1. Indicate the direction of slope for the garage slab, R309.1.
2. Provide a Roof Framing Plan showing the location and size of beams, headers, and rafters for supporting live and dead structural loads, R804.

STRUCTURAL PLANS:

1. Provide a complete Roof Framing Plan showing the headers sized for supporting live and dead structural loads at each wall opening (Table R602.7(3)). A single 2x6 rafter may not perform as a header.
2. Provide manufacturer’s calculations and data for pre-engineered trusses dated and wet-sealed by an engineer who is registered in Arizona, or notate the requirement for deferred submittal, R106.1.
3. A site built roof requires a Roof Framing Plan showing the rafters sized for supporting live and dead structural loads (Table R802.4.1(1)) and roof structural members with rafter ties (or ceiling joists) and collar ties (ridge straps) when the roof pitch is equal or greater than 3” to 12”, R802.3.

SECTIONS - DETAILS:

1 Show a cross-section detail of the proposed exterior wall sheathing, R106.1.1. Show a minimum 3/8” structural sheathing.
2 Show ½” anchor bolts providing 7” embedment. Show the wall assembly with a 6” clearance above the ground or 2” clearance above an exterior concrete surface, R317.1 item 5.
3 The floor requires a slope for water runoff, R309.1, therefore the framed wall requires a concrete stem for achieving the 6” clearance between framing and ground (R317.1 item 5).
4 Show garage opening narrow panels with fastening details using a prescriptive method at Figure R602.10.6.2, R602.10.6.3 or R602.10.6.4.

ELECTRICAL PLANS:

1. Provide the feeder conductor size between the main panel and sub panel, E3602.1 & E3705.1.
2. Show all garage receptacle outlets with GFCI protection, E3902.2.

OUTDOOR LIGHTING CODE

1. Show compliance with the City of Tucson Outdoor Lighting Code with full cutoff fixtures when located within 25 feet from a property line OLC 401.3.3.

If you have any questions, please contact:
PDSD-Residential@tucsonaz.gov
City of Tucson Residential Plan Review
03/11/2025 Site Zoning - Standard REQUIRES RESUBMIT FROM: PDSD Zoning Review Section

PROJECT: TC-RES-0125-00301
239 N WESTMORELAND AV . – R-2
Detached garage (1st Review)

TRANSMITTAL DATE: March 10, 2025

COMMENTS: Resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This site is located in the R-2 zone (UDC 4.7.9). A Single-family, Attached is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.6, .9, & .10.

1. Provide a residential plot plan that meets the requirements found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Building-Safety/Plan-Examples/Plot-Plan-Example, to include but not limited to:
a. The plot plan shall show the entire parcel.
b. The plot plan shall be drawn at an engineering scale, i.e. 1” = 10’, 1” = 20’.
c. The plot plan shall show all structures on the parcel along with perimeter yard setback dimensions.
d. The lot coverage calculation shall include all structures on the parcel.
e. Show the zoning of the parcel and all adjacent parcels on the plot plan.
f. Show all utility lines on the plot plan.
g. Provide the legal description, “MENLO PARK LOT 5 BLK 6” on the plot plan.
h. Provide a dimension from the centerline of Westmoreland Ave. to the face of curb, where pavement meets the concrete curb, and from face of curb to the east property line. Per Construction Plan I-67-023, sheet 11, found at: https://maps-and-records.tucsonaz.gov/construction-plans/details/I-67-023, the distance from centerline to curb is 18’, and from face of curb to property line is 12’.

2. Zoning acknowledges that you provided a neighbors setback waiver. This waiver shall be provided on the plot, signed and dated.

3. Per UDC Article 6.4.5.C.1.a, the required front street perimeter yard setback is 20’-0”, proposed setback is 18’-0”. A Design Development Option (DDO) must be submitted and approved to reduce the required setback. DDO application and requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration. If you have questions about the DDO application or process please contact Georgia Pennington at Georgia.Pennington@tucsonaz.gov”.

4. Based on aerial photos the “Existing Covered Porch” shown on the plan shows up on site some time after 2020. Zoning was not able to find approved permit documents for this structure and a building permit is required. Provide permit documents for the porch. Clearly show the post supporting the porch and provide perimeter yard setback dimensions to the applicable property lines

5. Based on aerial photos there is a porch structure on the west side of the west residence that shows up on site sometime after 2020. Zoning was not able to find approved permit documents for this structure. A separate permit is required for this structure.

6. Based on aerial photos there is what appears to be a shed structure located along the south property line that appears some time after 2020. Zoning was not able to find approved permit/compliance review documents for this structure. If this structure is greater than 200 sq. ft. a building permit is required, if less than 200 sq. ft. Zoning compliance is required. Show this structure on the plan along with the square footage, wall heights and perimeter yard setback dimensions. If this structure does not meet the minimum 6’-0” setback, UDC Table 6.3-2.A to the south property line at a minimum a neighbors setback waiver will be required, UDC Article 6.6.2.D. To secure this neighbor’s setback waiver the following statement must be provided on the plot plan and be signed and dated by the adjacent property owner(s):
My Name is____________________ and I am the owner of the property located at_______________________. I have reviewed the site plan, and I have no objection to structure being located or constructed________ feet from the property line as depicted on the site plan.

Signature: _____________________________

Date: _________________________________
If you are not able to secure the waiver a DDO will be required.

7. Based on aerial photos there is a site fence that appears sometime after 2020. Zoning was not able to find approved Zoning compliance documents for this fence. Clearly show the fence on the plot plan and provide the height.

The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
02/10/2025 PDSD Application Completeness Express REVIEW COMPLETED