Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.2
Permit Number - TC-RES-0125-00272
Review Name: RESIDENTIAL NEW DWELLING v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/07/2025 | Site Engineering - Standard | NOT REQUIRED | |||
| 03/07/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 02/20/2025 | Residential Building - Standard | REQUIRES RESUBMIT | TC-RES-0125-00272 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance. Note the 2018 IRC reference on the plans. 1. Field welding requires a completed special inspection request form for review with the permit plans, R109.2. Obtain an inspector and provide a certified inspector seal on the form found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Building-Inspections Provide a response letter addressing each comment with location of change on the plans. Submit separate letter and plan set files. PLANS: 1. The roof structure may not extend to a point closer than 3 feet from the neighboring property line without fire rated protection for fire spread. Provide compliance with R302.1 (City of Tucson Amended) by protecting the structure placed within 3 feet of the property line in compliance with IBC Table 721.1(2). Include a one hour rated wall below the roof edge with foundation along the full length of structure near the property line. If you have any questions, please contact: PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services ---------------------- |
||
| 03/04/2025 | Site Zoning - Standard | REQUIRES RESUBMIT | FROM: PDSD Zoning Review PROJECT: TC-RES-0125-00272 1638 N JEFFERSON AV . – R-2 Detached Carport (1st Review) TRANSMITTAL DATE: March 4, 2025 Resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in the R-2 zone (UDC 4.7.9). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.6, .9, & .10. 1. The lot coverage calculation is not correct. Per UDC Article 6.4.3.C.1.a Roofed areas, porches, open on at least one side are not included in the calculation. COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1). 1. Per UDC Article 6.4.5.D.3.a Shade structures or carports may project up to ten feet into required perimeter yards. The proposed setback from the proposed detached carport to the Jefferson Ave. street property line is 1’-0”. A Design Development Option (DDO) must be submitted and approved to reduce the required setback. DDO application and requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration. If you have questions about the DDO application or process please contact Georgia Pennington at Georgia.Pennington@tucsonaz.gov”. 2. Perimeter yard setbacks are based on a wall height measurement from design grade to the highest point of the exterior wall UDC Article 6.4.5.B & Figure 6.4.5-A. Per UDC Article 6.4.5.B.2 for a carport type structure the height measurement is from design grade to the top of beam supporting the roof of the carport. As elevation drawings were not provided with dimensions from design grade to top of beam, at it’s highest point, Zoning cannot determine the required perimeter yard setback from the proposed carport to the north property line. The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A). At a minimum a neighbors setback waiver, UDC Article 6.6.2.D, will be required for the reduced 1’-0” perimeter yard setback. To secure this neighbor setback waiver the following statement must be provided on the plot plan and be signed and dated by the property owner to the north: My Name is____________________ and I am the owner of the property located at_______________________. I have reviewed the site plan and I have no objection to structure being located or constructed________ feet from the property line as depicted on the site plan. Signature: _____________________________ Date: _________________________________ If you are not able to secure the required waiver the setback can be addressed using the DDO process mentioned above. The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 02/04/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |