Permit Review Detail
Review Status: In Review
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0125-00148
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: In Review
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
02/18/2025 | Fire New Construction Complex | NOT REQUIRED | |||
02/03/2025 | Site Landscape Complex | NOT REQUIRED | |||
N/A | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
N/A | Historic Complex | PENDING ASSIGNMENT | |||
N/A | Site Engineering Complex | PENDING ASSIGNMENT | |||
02/04/2025 | Residential Building Complex | REQUIRES RESUBMIT | Provide a complete construction plan set showing 2018 IRC and City of Tucson building ordinance compliance after DDO approval. | ||
02/14/2025 | Site Zoning Complex | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Krista Hansen Planning & Development Services Department – Zoning Review Section PROJECT: TC-RES-0125-00148 407 E 2nd St, Tucson, AZ 85705 Detached Secondary Dwelling (1st Review) TRANSMITTAL DATE: 2/14/2025 This site is located in the HR-3 zone (UDC 4.7.12). A detached secondary dwelling is a permitted use in this zone. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised plans, as noted in the comments below, along with a detailed letter indicating responses to the review comments. 01. COMMENT: The area labeled as “Alley No Name” does not appear to be public right-of-way. It has a tax code that is assigned to the State of Arizona. Remove label. 02. COMMENT: It appears access off of Parcel ID #117022640. Please provide recorded easement information documenting any formal vehicular access to the north side of the property. 03. COMMENT: Dimension the driveway north of the carport and include that calculation in the vehicular use area and total lot coverage. 04. COMMENT: It appears the structure you are proposing to demolish may be over 50 years old. Architectural documentation is required prior to demolishing. Any structure over 50-years old needs to be reviewed prior to demolition. Reach out to Michael.Taku@tucsonaz.gov for further direction. 05. COMMENT: As shown on the project description, actual setbacks do not meet the minimum requirements. Per UDC TABLE 6.3-2.A, the minimum requirements are 6’ or 2/3 the height. Based on a proposed western wall height of 21’-6”, a 14’-4” setback would be required. The proposed setback from the western property line is 9’-7”. Based on a proposed northern wall height of 21’-6”, a 14’-4” setback would be required. The proposed setback from the northern property line is 0’0”. Based on a proposed eastern wall height of 21’-6”, a 14’-4” setback would be required. The proposed setback from the eastern property line is 6”. As this property is located within an HPZ, historic review will be required. Reduced setbacks may be granted through this process. For submittal requirements, please reach out to Michael.Taku@tucsonaz.gov. For questions regarding Zoning comments, please contact me at: Krista.Hansen@tucsonaz.gov |
||
01/29/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |