Permit Number: TC-RES-0125-00119
Parcel: 126163060

Review Status: Requires Resubmit

Review Details: RESIDENTIAL FENCE/WALL v.2

Permit Number - TC-RES-0125-00119
Review Name: RESIDENTIAL FENCE/WALL v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
02/03/2025 Residential Building NOT REQUIRED
02/12/2025 Site Engineering NOT REQUIRED
02/14/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
02/14/2025 Site Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Bobby Parsons
Zoning Section Review

PROJECT: TC-RES-0125-00119
3954 E Whittier St Tucson, AZ 85711
Replace existing wood fence with new Corrugated Steel Privacy fence along road facing property line (1st Review)

TRANSMITTAL DATE: 2/14/2025

This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 - .9.

Comments: Please resubmit revised drawings along with a detailed response letter which states how all Zoning Review Section comments were addressed.

1. Comment: Per UDC 6.6.2.I, the maximum height of a wall or fence within a perimeter yard shall be 6’, however, the wall or fence may be higher than 6’ but no higher than 10’ if:
• At least 75% of the area above 6’ in height is left unobstructed and open through the use of architectural elements such as arches, columns, wrought iron;
• Part of, or located on top of, a retaining wall no higher than 10’ measured from design grade and no higher than 6’ measured from the top of the retaining portion of the wall;
• A greater height is required through the rezoning process or the special exception land use process; or
• A greater height is required by a specific UDC standard.
The proposed privacy fence is 7’ which exceeds the maximum allowed height of a wall and does not meet the criteria above. Either reduce the height of the fence to 6’ or apply for a Design Development Option (DDO) to increase the allowed height of the proposed fence to 7’. Please reach out to Georgia Pennington at Georgia.Pennington@tucsonaz.gov or Mark Castro at Mark.Castro@tucsonaz.gov if you have questions about the DDO process. Here is a link with information about the DDO process: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration#section-3.
2. Comment: Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted.

If you have any questions about this transmittal, please contact Bobby Parsons at Robert.Parsons@tucsonaz.gov.