Permit Number: TC-RES-0125-00052
Parcel: 123053650

Review Status: Requires Resubmit

Review Details: RESIDENTIAL FENCE/WALL v.3

Permit Number - TC-RES-0125-00052
Review Name: RESIDENTIAL FENCE/WALL v.3
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
02/18/2025 Residential Building NOT REQUIRED
03/04/2025 Site Engineering NOT REQUIRED
03/04/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
03/03/2025 Site Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Bobby Parsons
Zoning Section Review

PROJECT: TC-RES-0125-00052
2301 E Waverly Street Tucson, AZ 85719
Replace a wood fence with a slump block wall 112 feet long not exceeding 7 feet in height. (1st Review)

TRANSMITTAL DATE: 3/3/2025

This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 - .9.

Comments: Please resubmit revised drawings along with a detailed response letter which states how all Zoning Review Section comments were addressed.

1. Comment: Per UDC 6.6.2.I, the maximum height of a wall or fence within a perimeter yard shall be 6’, however, the wall or fence may be higher than 6’ but no higher than 10’ if:
• At least 75% of the area above 6’ in height is left unobstructed and open through the use of architectural elements such as arches, columns, wrought iron;
• Part of, or located on top of, a retaining wall no higher than 10’ measured from design grade and no higher than 6’ measured from the top of the retaining portion of the wall;
• A greater height is required through the rezoning process or the special exception land use process; or
• A greater height is required by a specific UDC standard.

The proposed wall is 80” which exceeds the maximum allowed height of a wall and does not meet the criteria above. Either reduce the height of the wall to 6’ or apply for a Design Development Option (DDO) to increase the allowed height of the proposed wall to 80”. Please reach out to Georgia Pennington at Georgia.Pennington@tucsonaz.gov or Mark Castro at Mark.Castro@tucsonaz.gov if you have questions about the DDO process. Here is a link with information about the DDO process: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration#section-3.
2. Comment: Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted.

If you have any questions about this transmittal, please contact Bobby Parsons at Robert.Parsons@tucsonaz.gov.
02/14/2025 PDSD Application Completeness Express REVIEW COMPLETED