Permit Number: TC-RES-0125-00022
Parcel: 138230140

Address:
724 W CALLE RITA

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - TC-RES-0125-00022
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
02/03/2025 Site Engineering NOT REQUIRED
02/03/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
01/13/2025 Residential Building REQUIRES RESUBMIT TC-RES-0125-00022
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance. The plans require sufficient detail for demonstrating minimum building code compliance for passing all progress inspections. A permit will not be issued for a portion of a structure without assuring a complete code compliant structure is feasible.

Note the 2018 IRC reference on the plans.

The plans may require the identification of a complete building showing 2018 IRC compliance. Clarify if the proposed foundation is sufficient for supporting the unidentified structure with appropriate clearance above grade.

Provide a response letter addressing each comment with location of change on the plans. Submit separate letter and plan set files.

Provide a clear and concise construction plan set. Sample drawings are available for understanding details. Sample plans at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits

SITE PLAN:

1. Show the location and size of buildings, utility meters and gas, water, electric and sewer or septic lines from property line to building, R106.1.1. Identify the utility lines requiring upgrade or replacement.
2. Show the square footage of living space, garage, and covered patios, R106.1.1.
3. Show the distance of proposed structure to the property lines with a minimum 3-foot clearance or include the requirement for one hour rated construction, R302.

PLANS:

1. Provide a complete floor plan showing the functional name of each existing and proposed room, R106.1.1. Existing bedrooms with removed windows must show code compliance for egress, R310. Include any alteration of door or window openings between existing and proposed rooms.
2. Provide a Roof Framing Plan showing the rafters sized for supporting live and dead structural loads (Table R802.4.1(1)) or provide an engineer’s sealed plan set for manufactured trusses, R301.1.3.

SECTIONS - DETAILS:

1. Show exterior wood siding, sheathing and wall framing with a 6” clearance above the ground (R317.1 item 5). The weep screed may extend with a minimum clearance 4” above grade or 2” above paved areas, R703.7.2.1.
2. Show any proposed roof overhang dimension, R802.7.1.1.

PLUMBING PLANS:

1. Identify any proposed alterations.

MECHANICAL PLANS:

1. Identify any proposed alterations.

ELECTRICAL PLANS:

1. Identify any proposed alterations.

If you have any questions, please contact:
PDSD-Residential@tucsonaz.gov
City of Tucson Residential Plan Review

Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services
----------------------
01/31/2025 Site Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Bobby Parsons
Zoning Section Review

PROJECT: TC-RES-0125-00022
724 W Calle Rita Tucson, AZ 85756
Add Concrete for foundation 16' x 12' with 2 number/ 4 1/2 inch rebar continuous. Square footage is approximate. (1st Review)

TRANSMITTAL DATE: 1/31/2025

This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 - .9.

Comments: Please resubmit revised drawings along with a detailed response letter which states how all Zoning Review Section comments were addressed.

1. Comment: Site zoning is unable to conduct a full review with the submitted documents. Please include a site plan in your next submittal which includes the information noted in the sample site plan. Please see https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/residential_plot_plan_requirements.pdf for reference. Also, please clarify why the included document states porches and addition. Will they be included in the scope of work with this permit?
2. Comment: Additional comments may be forthcoming depending on plans resubmitted and responses to these zoning review comments.

If you have any questions about this transmittal, please contact Bobby Parsons at Robert.Parsons@tucsonaz.gov.
01/03/2025 PDSD Application Completeness Express REVIEW COMPLETED