Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.3
Permit Number - TC-RES-0124-00563
Review Name: RESIDENTIAL NEW DWELLING v.3
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/22/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 04/22/2024 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review PROJECT: TC-RES-0124-00563 1134 N 6TH AV. – C-2 Duplex (3rd Review) TRANSMITTAL DATE: April 22, 2024 Please resubmit revised drawings detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in the C-2 zone (UDC 4.7.21). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-4). 1. The dimensions providing on the plan set for the height of the proposed structure do not clearly identify the proposed height. Using the scale provided for the building elevations on the plan set, the below building heights and setback requirements were found. 2. COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1). The minimum setback is the greater of ten (10) feet, or three-quarters (3/4) the height of the structure’s wall facing each interior property line (Table 6.3-3.A). Based on a wall height of 35’-0” the required perimeter yard setback from the proposed duplex to the north property line is 26’-3”, proposed setback is 5’-2”. Based on a wall height of 34-0” the required perimeter yard setback from the proposed duplex to the south property line is 25’-6”, proposed setback is 5’-2”. The setback to the east will have two setback requirements. One will be based on the height of deck. A height was not provided for the deck. It appears that the highest point of the deck is 24 feet. The required setback for the deck is 18 feet from the east property line. The second setback for the east property line will be based on the highest point of the building wall height of 35’-0”. The required perimeter yard setback from highest point of the building wall to the east property line is 26’-3”, proposed setback is 20’-0”. Based on a wall height of 35'-0" the required perimeter yard setback from the proposed duplex to the west property line is 26'-3", proposed setback is 7'-0" If you have questions about the DDO application or process please contact Wyatt Berger at Wyatt.Berger@tucsonaz.gov or Georgia Pennington at Georgia.Pennington@tucsonaz.gov. |
||
| 04/02/2024 | Zoning Modifications - DDO | REQUIRES RESUBMIT | DDO-24-30 has been withdrawn by the applicant based on noncompliance with specific finding UDC 3.11.1.D.2.b. Contact me at Wyatt.Berger@tucsonaz.gov or at 520-837-4951 if you have questions about the DDO process. |
||
| 03/20/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |