Permit Number: TC-RES-0124-00561
Parcel: 136345620

Address:
3542 S CHESIN DR

Review Status: Requires Resubmit

Review Details: RESIDENTIAL SIMPLE REVIEW v.2

Permit Number - TC-RES-0124-00561
Review Name: RESIDENTIAL SIMPLE REVIEW v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
02/01/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
02/01/2024 Light Residential Building Review (OIP) REQUIRES RESUBMIT Permit Review TC-RES-0124-00561 (3542 S CHESIN DR TUCSON, AZ 85730)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.
Code reference, 2018 International Residential Code (IRC).

1. To justify using the 1" pipe you will need to use the low-pressure gas equation (G2413.4(1) equation 24-3, see also IFGC 2018 402.4(1) equation 4-1) and analyze each segment of the piping, including the equivalent length for each fitting. The gas pressure at the two appliances would need to be greater than the minimum required gas pressure for each appliance.

Otherwise, an appeal to the building official is required.
https://www.tucsonaz.gov/Departments/Planning-Development-Services/PDSD-Sandbox/Building-Code-Modification-Appeals

Building code appeal is found under sub-records.

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov