Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.3
Permit Number - TC-RES-0124-00547
Review Name: RESIDENTIAL NEW DWELLING v.3
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/06/2024 | Residential Building | APPROVED | |||
| 04/23/2024 | Fire New Construction | NOT REQUIRED | |||
| 04/22/2024 | Historic | NOT REQUIRED | |||
| 05/20/2024 | Site Engineering | NOT REQUIRED | |||
| 05/15/2024 | Site Landscape | NOT REQUIRED | |||
| 05/20/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 05/20/2024 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-RES-0124-00547 1113 E ALTA VISTA ST. – R-2 Laundry and Closet Addition (2nd Review) TRANSMITTAL DATE: May 20, 2024 COMMENTS: Resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in the R-2 zone (UDC 4.7.9). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.6, .9, & .10. 1. Provide a residential plot plan that meets the requirements found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Building-Safety/Plan-Examples/Plot-Plan-Example, to include but not limited to: a. This comment was not addressed correctly. The north/south dimension should be 126’ and the east/west should be 55’, see the Assessor’s Record Map found at: https://www.asr.pima.gov/ParcelData/Map/Arm/MP06/06085.pdf. Provide the property dimensions on the plot plan. 2. This comment was not addressed. No dimension from design grade to the highest point of the wall was provided on the east elevation. Based on a measurement taken using Bluebeam review software, at the highest point of the laundry addition the height is about 9’-8” which requires a 6’-6” perimeter yard setback to the west property line. Perimeter yard setbacks are based on a wall height measurement from design grade to the highest point of the exterior wall UDC Article 6.4.5.B & Figure 6.4.5-A. Where the wall meets the eave of the roof. Per UDC Table 6.3-2.A the minimum perimeter yard setback from the proposed addition to the west property line is 6’-0” or 2/3 (H) height of the building exterior wall, great of the two. Based on a wall height of less than 9’-0” the requirement setback from the addition to the west property line is 6’-0”, based on the dimensions shown on sheet A105 the proposed setback is 5’-4”. A Design Development Option (DDO) must be submitted and approved to reduce the required setback. DDO application and requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration. If you have questions about the DDO application or process please contact Wyatt Berger at Wyatt.Berger@tucsonaz.gov or Georgia Pennington at Georgia.Pennington@tucsonaz.gov. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 04/22/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |