Permit Number: TC-RES-0124-00495
Parcel: 136126430

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.4

Permit Number - TC-RES-0124-00495
Review Name: RESIDENTIAL NEW DWELLING v.4
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
05/30/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
05/14/2024 Residential Building REQUIRES RESUBMIT TC-RES-0124-00495 3rd
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

GENERAL REQUIREMENTS:

1. Provide a response letter for each comment, R106.1.

2. Provide a complete plan set of all sheets shown on the index, R106.1.

SITE PLAN:

1. Show the location of proposed the electrical feeder from the service panel to the ADU, R106.1.1.

SECTIONS - DETAILS:

1. An unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing, R806.5. Show a roof design with insulation types and minimum thickness for meeting the condensation control requirement and the minimum total insulation value of R-38. Show air-permeable insulation directly under the air-impermeable insulation without air gaps, R806.5.5.1.3 or provide the attic vent opening size calculation using 1 to 150 of attic area in compliance with R806.2 and show a minimum 1” ventilation clearance between ceiling insulation and roof sheathing over the wall and eave area if eave vents are used, R806.3. This may be accomplished w/ baffles.

INTERNATIONAL ENERGY CONSERVATION CODE:

1. Energy Certificate: (Mandatory) place near the indoor furnace or in utility room, N1101.14. Add notation to plans.

If you have any questions, please contact:
PDSD-Residential@tucsonaz.gov
City of Tucson Residential Plan Review

Submit a corrected plan set at https://www.tucsonaz.gov/pdsd
05/30/2024 Site Zoning REQUIRES RESUBMIT ZONING REVIEW TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT:
TC-COM-0524-00943
2445 N ORACLE RD. – C-2
Temp fencing for construction (1st Review)

TRANSMITTAL: May 30, 2024

This comment was not addressed. Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This site is located in C-2 Zone (UDC 4.7.21).

1. A Temporary Use Permit. (TUP) is required for the construction trailer and must be approved prior to approval of this permit. TUP requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration#section-8.

If you have any questions about this transmittal, contact Nicholas Martell at (520) 837-6933 or email Nicholas.Martell@tucsonaz.gov.
05/01/2024 PDSD Application Completeness Express REVIEW COMPLETED