Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL FENCE/WALL v.2
Permit Number - TC-RES-0124-00413
Review Name: RESIDENTIAL FENCE/WALL v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/29/2024 | Residential Building | NOT REQUIRED | |||
| 02/01/2024 | Site Engineering | NOT REQUIRED | |||
| 02/01/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 01/30/2024 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-RES-0124-00413 6417 E CALLE HERCULO – R-1 Fence Addition (1st Review) TRANSMITTAL DATE: January 30, 2024 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 – 9 1. Provide the proposed height of the fence on the plan. Per Unified Development Code (UDC) Article 6.6.2.I The maximum height of a wall or fence within a perimeter yard shall be six feet. 2. Based on current aerial photos there are two (2) what appear to be shed structures, one (1) in the northwest corner of the site and one (1) along the east side of the property. Zoning was not able to find approved compliance review documents for these structures. Either provide approved compliance review documents or provide a residential plot plan that meets the requirements found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Building-Safety/Plan-Examples/Plot-Plan-Example, and show the new fence location and the sheds along with the height of the shed structures and perimeter ;yard setback dimensions to the applicable property lines. If either shed does not meet the minimum perimeter yard setback requirements of 6’-0” or 2/3 (H), the height of the exterior wall, great of the two at a minimum a neighbors setback waiver will be required. To secure this neighbor setback waiver the following statement must be provided on the plot plan and be signed and dated by the adjacent property owner(s): My Name is____________________ and I am the owner of the property located at_______________________. I have reviewed the site plan and I have no objection to structure being located or constructed________ feet from the property line as depicted on the site plan. Signature: _____________________________ Date: _________________________________ If you are not able to secure a setback waive a Design Development Option (DDO) will need to be submitted and approved for the reduced setback, DDO application and requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration. If you have questions about the DDO application or process please contact Wyatt Berger at Wyatt.Berger@tucsonaz.gov or Georgia Pennington at Georgia.Pennington@tucsonaz.gov. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 01/26/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |