Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TC-RES-0124-00388
Parcel: 127081080

Address:
5331 E 8TH ST

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.2

Permit Number - TC-RES-0124-00388
Review Name: RESIDENTIAL NEW DWELLING v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
05/22/2024 Bldg Permits - Post Review PENDING ASSIGNMENT
05/07/2024 Residential Building REQUIRES RESUBMIT TC-RES-0124-00388 2nd
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance with component sizes.

Provide a clear and concise construction plan set showing all fastening methods as illustrated in the sample drawings for an attached porch covering - see Porch Sample. Sample plans are available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits

STRUCTURAL PLANS:

1. Provide a Roof Framing Plan showing appropriate beam sizes for supporting live and dead structural loads, R804. A 4 x 4 beam is undersized for a span greater than 10 feet.
2. Specify method of transferring lateral forces from the roof diaphragm to the existing dwelling, R801.2. Show a ledger with compliant fasteners or rafters on dwelling top plate with fasteners.

SECTIONS - DETAILS:

1 Show reinforced footing dimensions required for post/beam construction, R403.1.1.
2 Show a complete cross-section detail with post to foundation fasteners, R407.3 & R507.4.1.
3 Show ½”structural roof sheathing and fastening in compliance with Table R602.3 (1).
4 Identify all fasteners for wind loading compliance. Show roof (uplift resistance) fasteners (H2.5) with appropriate uplift capacity, R802.11 amended.

If you have any questions, please contact:
Ken Van Karsen
PDSD-Residential@tucsonaz.gov
City of Tucson Residential Plan Review
05/22/2024 Site Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL FROM: Georgia Pennington Planner

PROJECT: TC-RES-0124-00388
5331 E 8th St – R-1
Porch and Gazebo (2nd Review)

TRANSMITTAL DATE: May 22, 2024

COMMENTS: Resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 - .9.

1. Provide a complete plot plan that includes all the required elements. Use this link for guidance: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Plan-Examples/Plot-Plan-Example Specifically:
a. This comment was not addressed. The plot plan is not drawn to a scale and no scale was provided. Indicate the scale of the plan (example 1” = 10’).
b. This comment was not addressed. Legal Description.
c. This comment was not addressed. Square footage of lot, existing dwelling, proposed additions, and accessory structures.
d. This comment was not addressed. Provide lot coverage calculation.
e. This comment was not addressed. Provide zoning on the property and surrounding properties.
f. The property dimensions are not correct. The east/west dimension should be 86’ and the north/south should be 105’

2. This comment was not addressed. Provide elevations showing height of both the gazebo and porch from design grade to the highest point of the post for both structures.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
04/23/2024 PDSD Application Completeness REVIEW COMPLETED