Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0124-00365
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/23/2024 | Fire New Construction | NOT REQUIRED | |||
| 02/12/2024 | Site Engineering | NOT REQUIRED | |||
| 02/12/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 01/30/2024 | Historic | REQUIRES RESUBMIT | 4813 E CALLE JABALI—This is a contributor to the Aldea Linda National Register historic district so you will need to provide full historic demolition documentation. Application and checklist found here: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/planning-amp-zoning/historic_demolition_application_form.pdf Questions? Contact James.Gardner@tucsonaz.gov |
||
| 02/01/2024 | Residential Building | REQUIRES RESUBMIT | TC-RES-0124-00365 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. PLANS: 1. Provide manufacturer’s calculations and data for pre-engineered trusses dated and wet-sealed by an engineer who is registered in Arizona, or notate the requirement for deferred submittal, R106.1. SECTIONS - DETAILS: 1. Show joist/rafter bearing contact to a wall or beam structure with foundation without fascia nailing, R502.6 & R802.6. Replace the rafter connection to fascia at detail #5/9 or provide a registered Arizona engineer design analysis with sealed plan. 2. Show the wall assembly with a 6” clearance above the ground or 2” clearance above an exterior concrete surface, R317.1 item 5. Update detail #3/9. 3. An unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing, R806.5. Show a roof design with insulation types and minimum thickness for meeting the condensation control requirement and the minimum total insulation value of R-38 or R-30 when extended over the wall top plate for additions under 500 SF. Update section A/5 and detail #1 & 2/9. PLUMBING PLANS: 1. Provide complete plumbing plans showing any changes with 2018 IRC compliance, R301.1. Include the outdoor kitchen. ELECTRICAL PLANS: 1. Interior alterations require the installation of smoke alarms in existing bedrooms, R314.2.2. Provide notation if the smoke alarms are existing or proposed. 2. Show Bathroom receptacles with a separate 20 AMP dedicated circuit, E3703.4 and E3901.6. Update keynote #19. 3. Notate interior 15A & 20A circuits serving outlet locations (except garage, kitchen, and bathrooms) including receptacles, lights and smoke detectors with combination type arc-fault circuit interrupters, E3902.16. Update keynote #20. If you have any questions, please contact: PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services |
||
| 01/24/2024 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: Wyatt Berger Lead Planner PROJECT: TC-RES-0124-00365 4813 East Calle Jabali – R-1 New four-car garage, master bath, and porch (1st Review) TRANSMITTAL DATE: January 24, 2024 Please resubmit revised drawings with a detailed response letter stating how all Zoning Review Section comments were addressed. 1. Provide a lot coverage calculation on the site plan. Lot coverage includes the area of the site covered by buildings, outdoor storage areas, and driveways, whether paved or unpaved (UDC 6.4.3.B.3). Pergolas and patios are excluded from the lot coverage calculation (UDC 6.4.3.C.1.a). Lot coverage shall not exceed 70% in the R-1 zone (UDC Table 6.3-2.A). 2. Indicate the maximum height of the proposed pergola. Per UDC 6.6.3.D, accessory structures shall not exceed 12 feet in height, unless attached to a principal structure. A Board of Adjustment variance is required to be granted to allow an accessory structure to exceed the requirements of this section. 3. The existing detached carport to the west of the residence appears to be proposed for demolition. The property is located within the Aldea Linda National Historic District. The existing carport also appears in aerial photography as early as 1958. The structure must be architecturally documented prior to demolition (UDC 3.12.1). Documentation shall be reviewed and approved by the City Historic Preservation Office prior to Zoning approval of TC-RES-0124-00365. The Demolition of Historic and Older Structures Application and General Information may be downloaded at: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/planning-amp-zoning/historic_demolition_application_form.pdf. If you have any questions about this review, contact me at Wyatt.Berger@tucsonaz.gov or at 520-837-4951. |
||
| 01/23/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |