Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.4
Permit Number - TC-RES-0124-00336
Review Name: RESIDENTIAL NEW DWELLING v.4
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
03/13/2024 | Residential Building | APPROVED | PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance. Place a sheet number on each page of the construction plan set and submit as a single PDF file. Submit the comment letter into a separate PDF file. Revise the panel schedule showing appropriate wire and breaker sizes for the connected loads. Refer to Table E3705.5.3 for sizing branch circuit conductors and protection ratings. 14 gauge wire is protected with a 15 AMP breaker. 12 gauge with 20 AMP. 10 gauge with 30 AMP. 8 gauge with 40 AMP. Place the arc fault note on the electrical plan: "Protect interior 15A & 20A circuits serving outlet locations (except garage, kitchen, and bathrooms) including receptacles, lights and smoke detectors with combination type arc-fault circuit interrupters". |
||
03/21/2024 | Site Engineering | NOT REQUIRED | |||
04/05/2024 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
04/05/2024 | Site Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL Nicholas Martell, Principal Planner TC-RES-0124-00336 Residential Interior Remodel April 5, 2024 The commercial plans have been reviewed by the Zoning Review Section but cannot be approved until all zoning comments or concerns have been addressed. 1. The site appears to have 3 units in total. By UDC definition, this site is likely a multi-family residential site: UDC 11.3.7 "Multifamily Development: Any residential development consisting of three or more dwelling units on an integrated site or single lot" 2. If this site is a multifamily development a development package, meeting the standards of Administrative Manual 2-06 will be required: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-8753 3. If this site is does not have 3 units, please provide a floor plan of all buildings for zoning to review. If you have any questions about this transmittal, please contact me at Nicholas.Martell@tucsonaz.gov |
||
03/01/2024 | PDSD Application Completeness | REVIEW COMPLETED |