Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0124-00261
Parcel: 126181990

Review Status: Requires Resubmit

Review Details: RESIDENTIAL SOLAR v.2

Permit Number - TC-RES-0124-00261
Review Name: RESIDENTIAL SOLAR v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
01/30/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
01/30/2024 Light Residential Building Review (OIP) REQUIRES RESUBMIT Permit Review TC-RES-0124-00261 (4210 E PASEO GRANDE TUCSON, AZ 85711)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.
Code reference, 2018 International Residential Code (IRC), 2017 National Electrical Code (NEC).

1. Aerial views of the property show the overhead service conductors passing over the roof. The overhead service conductor over the structure requires an 8’ clearance above the roof, E3604.2.1. Show a mast height necessary to achieve this clearance. The necessary mast height at the existing panel location may not be a feasible installation and may require the relocation of the service entrance to a code compliant location.

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov
01/25/2024 PDSD Application Completeness Express REVIEW COMPLETED