Permit Review Detail
Review Status: Approved
Review Details: RESIDENTIAL NEW DWELLING v.4
Permit Number - TC-RES-0124-00247
Review Name: RESIDENTIAL NEW DWELLING v.4
Review Status: Approved
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/18/2024 | Residential Building | APPROVED | Approved with the following comments added to the plans: 1. Protect a cleanout plug from the loads of vehicular traffic. Cleanout assemblies in accordance with ASME A112.36.2M Shall be installed, P3005.2.10.2. 2. Removed (2) 2x12 beam as an option. This beam option is undersized for the given load and span. 3. Garage Branch Circuit: a separate (dedicated) GFCI 20-amp branch circuit required for receptacles in an attached garage, E3703.5. 4. All garage receptacle outlets with GFCI protection, E3902.2. Include the ceiling receptacle 5. Provide Full Cut-off Fixtures, 2012 OLC. |
||
| 06/27/2024 | Site Zoning | APPROVED | |||
| 06/27/2024 | Bldg Permits - Post Review Express | REVIEW COMPLETED | |||
| 06/07/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |