Permit Number: TC-RES-0124-00240
Parcel: 136126400

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - TC-RES-0124-00240
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
02/08/2024 Site Engineering NOT REQUIRED
02/12/2024 Bldg Permits - Post Review PENDING ASSIGNMENT
01/18/2024 Residential Building REQUIRES RESUBMIT Permit Review TC-RES-0124-00240 (10066 E LURLENE DR TUCSON, AZ 85730)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.
Code reference, 2018 International Residential Code (IRC), 2018 International Building Code (IBC), 2017 National Electrical Code (NEC).


Structural Plans:
1. The provided structural documents indicate welding is required for assembly of the structure. Welding requires Special Inspection, IBC 110.3.9, 110.3.10, 1705.3.1.
2. Provide a Special Inspection Certificate with Parts A and B completed.
https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/special_inspection_certificate.pdf

Electrical Plans:
3. The provided Plot Plan indicates a new electrical line to the new detached garage.
4. Provide an Electrical Plan, IRC E3401. Construction documents shall indicate the Main Panel and any Sub-Panel locations and shall provide information on wiring methods, circuiting and electrical load calculations which demonstrate that the premises electrical system has load capacity to accommodate the new electrical loads.
5. Provide a panel schedule showing panel size, circuit numbers, ampacity, wire size and general description, IRC E3404.13 & E3706.2. Provide a panel schedule showing wire size of each circuit or notate the wire size for each protection rating, IRC E3702.2.
6. Garage Branch Circuit: a separate (dedicated) GFCI 20-amp branch circuit required for receptacles in an attached garage and detached garages with service, IRC E3703.5.
7. Garage Receptacle Location: a 20 AMP receptacle outlet is required at each vehicle bay not more than 5.5 feet above the floor, IRC E3901.9.

Plumbing Plans:
8. The provided Plot Plan shows a new water line and septic line to the new detached garage.
9. Provide a floor/plumbing plan showing the location of all plumbing fixtures, and show hot/cold water lines on the floor plan, IRC R106.1.
10. Notate and specify all piping materials and sizes, IRC P2608.

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov
02/12/2024 Site Zoning REQUIRES RESUBMIT ZONING REVIEW TRANSMITTAL

FROM: Wyatt Berger
Lead Planner

PROJECT: TC-RES-0124-00240
10066 East Lurlene Drive – RX-1
Detached garage – (1st Review)

TRANSMITTAL DATE: February 12, 2024

Please resubmit revised drawings with a detailed response letter stating how all Zoning Review Section comments were addressed.

1. Combine all drawings into a single PDF document.

2. Clarify the size of the proposed garage. The site plan indicates that the dimensions of the garage are 31’ x 31’, while the engineered drawings indicate dimensions of 30’ x 30’.

3. The dimensions of the property are incorrect. Based on the Hearthstone Acres subdivision plat, the width of the subject lot is 175’ and the depth of the subject lot is 250’: https://maps-and-records.tucsonaz.gov/subdivisions/details/MP-28007&. Be aware that the required perimeter yard setback as measured from the east property line is 20' (UDC Table 6.3-1.A).

4. Per Tucson Unified Development Code (UDC) 6.6.3.D, accessory structures shall not exceed 12 feet in height, unless attached to a principal structure. Building height is the vertical distance measured from the design grade elevation to…the middle (between the eave and ridge) of the highest gable of a pitched or hipped roof (UDC 6.4.4.A).

Provide a dimension from the design grade elevation (the ground) to the middle (between the eave and ridge) of the highest gable of the roof. A variance is required to be granted by the Board of Adjustment if this dimension exceeds twelve feet. Contact Mark.Castro@tucsonaz.gov if you have any questions about the variance process.

If you have any questions about this review, contact me at Wyatt.Berger@tucsonaz.gov or at 520-837-4951.
01/17/2024 PDSD Application Completeness REVIEW COMPLETED