Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0124-00145
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/01/2024 | Site Engineering | NOT REQUIRED | |||
| 02/01/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 01/10/2024 | Residential Building | REQUIRES RESUBMIT | Permit Review TC-RES-0124-00145 (918 W CALLE GARCIA TUCSON, AZ 85706) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Residential Code (IRC). Provide a clear and concise construction plan set. Sample drawings are shown as an example: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits SITE PLAN: 1. Provide a complete site plan. Indicate the location and size of buildings, utility meters and lines supporting the alterations, R106.1.1. Show the utility lines requiring upgrade or replacement. STRUCTURAL PLANS: 2. Provide a Roof Framing Plan showing the location and size of beams, headers, and rafters for supporting live and dead structural loads, R804. Identify live and dead loads. Provide porch depth. R802.4.1. 3. Update the Porch Framing Plans to show the actual measurements of the structure you plan to build. Show the existing structure in the drawings. 4. On sheet 3/A, complete the Porch Column detail, including the column base, anchor bolt size and depth (per manufacturer’s requirements). 5. Show the untreated exterior posts above finished grade or metal post base with 1” space above concrete, R317.1.4 exception 1. 6. Provide consistent information on the Beam size and span. Sheet 3 shows a 4x6 beam while sheets 2/A and 4/B show a beam size of 4x8. No Beam span is given. 7. Provide a roof covering and underlayment rated for the given slope. Shingle roofs shall be used only on roof slopes (2:12 to 4:12), R905.2.2. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 01/09/2024 | Site Zoning | REQUIRES RESUBMIT | FROM: Paul Camarena PDSD Zoning Review Section PROJECT: TC-RES-0124-00145 918 W CALLE GARCIA Zoning R-1 New porch TRANSMITTAL DATE:January 9, 2024 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 1.COMMENT: Provide a Residential Plot Plan that meets the requirements found at: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/permits/residential-permits/residential_plot_plan_requirements.pdf This shall in include: a. Lot coverage calculation that meets the requirements of UDC Article 6.4.3 & the example shown on the residential plot requirements. (Lot coverage must include vehicular use area whether improved or unimproved) . Lot coverage does not include porches, UDC Article 6.4.3.C.1.a but does include vehicle use area measured within the outside edges of any area allocated to vehicle use, whether improved or unimproved. b. Zoning of adjacent parcels c. All Utility lines d. Property line distances 2.COMMENT: Draw dimension and label the height of the new structure measured from design grade to top of wall. 3.COMMENT: Ensure that the site plan includes everything on site. Additional comments may be forth coming. If you have any questions about this transmittal, Contact Paul Camarena at (520)837-4986 or by email Paul.Camarena@tucsonaz.gov |
||
| 01/09/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |