Review Date Reviewer's Name Type of Review Description Status Comments
02/01/2024 Site Engineering NOT REQUIRED
02/01/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
01/17/2024 Residential Building REQUIRES RESUBMIT TC-RES-0124-00103
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance with component sizes. The plans require sufficient detail for demonstrating an awareness of minimum building code compliance for passing all progress inspections.

SITE PLAN:

Provide a site plan showing dimensions of buildings and utilities, R106.1.1. Show the location of all utility lines from property line to building(s) along with required alterations. Include the utility lines to the proposed building.

SECTIONS - DETAILS:

1. An unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing, R806.5. Show a roof design with insulation types and minimum thickness for meeting the condensation control requirement and the minimum total insulation value of R-38 or R-30 when extended over the wall top plate for additions under 500 SF. Identify each layer on the plan.

PLUMBING PLANS:

1. Tucson Water Department limits flow rates for each water meter size in compliance with P2903.7. Show an appropriate yard pipe for supporting the existing and proposed dwelling units.

MECHANICAL PLANS:

1. Show heating/cooling facilities in all habitable rooms, R303.9. Include the bedroom.
2. Update the whole-house mechanical ventilation description, R303.4; N1103.6 & M1505.4. A one-bedroom dwelling space less than 1500 SF requires a 30 CFM continuous setting. Identify the continuous rated fan device or fresh air system.

ELECTRICAL PLANS:

1. Provide a Riser Diagram showing a sub panel and feeder size for proposed dwelling unit, NEC 225.30, E3403, Table E3704.2(1).
2. Show a smoke alarm in each bedroom and outside the doorway in the immediate vicinity, R314.3.

If you have any questions, please contact:
PDSD-Residential@tucsonaz.gov
City of Tucson Residential Plan Review

Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services
01/09/2024 Site Zoning REQUIRES RESUBMIT ZONING REVIEW TRANSMITTAL

FROM: Wyatt Berger
Lead Planner

PROJECT: TC-RES-0124-00103
701 West Santa Louisa Street – R-1
New guest house (1st Review)

TRANSMITTAL DATE: January 9, 2024

Please resubmit revised drawings with a detailed response letter stating how all Zoning Review Section comments were addressed.

1. Clarify whether the project is considered an accessory dwelling unit (ADU) or a sleeping quarters. An ADU may include a kitchen, bedrooms, bathrooms, and a sitting room (UDC 6.6.3.B). Per a Zoning Administrator’s determination dated May 29, 1996, for the construction to not be considered a dwelling, the project is limited to having a refrigerator that can fit below a sink counter, a wet bar sink, and no cooking facilities.

If an ADU is proposed, the revised plan set shall demonstrate compliance with all the requirements of UDC 6.6.3. Impact fees will also be incurred if an ADU is proposed. If a sleeping quarters is proposed, demonstrate how the site complies with use-specific standard 4.9.7.B.7 below.

For any new single-family dwelling in the R-1 zone with five bedrooms, three parking spaces are required. For every bedroom over five, one additional space is required for each bedroom. For all single-family dwellings in the R-1 zone with five or more bedrooms, all parking spaces may be located on-site, either in a side or rear perimeter yard. Parking spaces may not be located in a vehicular use area in any front street perimeter yard. A parking area is not required to be developed to a commercial standard. A dustproof parking surface is required to at least a minimum of two inches of compacted pea gravel. An existing covered residential parking area may be used.

2. Show all structures on the site plan. At least three detached accessory structures appear in the rear yard beginning in 2022. A Zoning compliance review was not obtained for these structures. These structures also do not appear to meet perimeter yard requirements. If these structures are to remain with reduced perimeter yards, provide signed neighbor’s setback waivers from the owners of 702 West Valencia Road and of 609 West Santa Louisa Street. The waivers are required to be pasted on the site plan and shall include the following language:

My name is _______ and I am the owner of property located at _______. I have reviewed the site plan and have no objection to the structure(s) being constructed or located __ feet from the property line as depicted on the site plan.

Signature: _______

Date: _______

3. Per UDC 6.4.5.C.1.b, where a lot abuts more than one street, the owner chooses which street lot line is the front lot line. From other the front lot line, the street perimeter yard is ten feet, as measured from the street property line. The proposed side street perimeter yard is 7’-0” as measured from the east property line.

If the required side street perimeter yard cannot be reasonably met, Design Development Option (DDO) approval is required to reduce the side street perimeter yard. The DDO application and requirements can be found at: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/planning-amp-zoning/2019_ddo_for_setback_and_height_udc.pdf. Submit a copy of your DDO application under permit number TC-RES-0124-00103. Contact Georgia.Pennington@tucsonaz.gov if you have questions about the DDO process.

If you have any questions about this transmittal, contact me at Wyatt.Berger@tucsonaz.gov or at 520-837-4951.
01/08/2024 PDSD Application Completeness Express REVIEW COMPLETED