Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0124-00078
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/29/2024 | Site Engineering | NOT REQUIRED | |||
| 01/29/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 01/11/2024 | Residential Building | REQUIRES RESUBMIT | TC-RES-0124-00078 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. GENERAL REQUIREMENTS: The City of Tucson adopted the 2018 IRC with amendments on 1/1/2019. Show the current code reference on the plans. Provide a complete construction plan set showing 2018 IRC compliance, R106.1. Clarify if the structure is a sleeping quarters (without kitchen) or an Accessory Dwelling Unit (ADU) which requires many alterations for compliance. Each dwelling unit with kitchen requires a separate Pima County assigned street address after Zoning approval, R319. https://www.pima.gov/1010/Addressing-Frequently-Asked-Questions An impact fee payment is required for an ADU at the time of permit payment. SITE PLAN: 1. Show the location and size of buildings, utility meters and gas, water, electrical, and sewer, R106.1.1. Each dwelling requires an appropriate source of electrical and water supply. Show the location and size of lines with connection points, R106.1.1. Identify the utility lines requiring upgrade or replacement. 2. Each dwelling unit should have an individual 3-foot clear space (including the roof projections) known as the fire separation distance for reducing fire spread to nearby buildings. Portions of buildings placed in a fire separation distance require one-hour fire-resistive construction in compliance with IBC Table 721.1(2). SECTIONS - DETAILS: 1. Provide concrete foundations for anchoring exterior framed wall sills with ½” anchor bolts with 7” embedment, R403.1.6 and with 6” minimum height above finished grade or 2” above paved areas for the enclosed vehicle door, R404.1.6. 2. Clarify the placement of ceiling/roof insulation for determining the need for an attic ventilation calculation or need for providing air-impermeable rigid insulation at the roof for condensation control, R806. 3. An unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing, R806.5. Show a roof design with insulation types and minimum thickness for meeting the condensation control requirement and the minimum total insulation value of R-38 or R-30 when extended over the wall top plate for additions under 500 SF. PLUMBING PLANS: 1. Tucson Water Department limits flow rates for each water meter size in compliance with P2903.7. Show an appropriate yard pipe for supporting the existing and proposed dwellings and show an appropriate water meter size. 2. Show an individual accessible water supply shut off and water heater for the proposed dwelling unit, P2903.9.1. MECHANICAL PLANS: 1. Show the HVAC system size for the building demand in accordance with M1401.3, M1601.1. 2. Provide (an HVAC system with fresh air intake) whole-house mechanical ventilation with controlled exhaust, R303.4; N1103.6 & M1505.4. Show the minimum airflow rate setting and location of the device requiring this adjustable setting. A one room dwelling under 1501 SF requires a 30 CFM continuous setting. ELECTRICAL PLANS: 1. Provide a Riser Diagram showing a service disconnect for each dwelling, NEC 225.30 and E3403. 2. Show the location of a smoke alarm, R314. 3. Interior 15A & 20A circuits serving outlet locations (except garage, kitchen, and bathrooms) including receptacles, lights, and smoke detectors require combination type arc-fault circuit interrupters, E3902.16. OUTDOOR LIGHTING CODE 1. Show full cutoff fixtures were located within 25 feet from the property line OLC 401.3.3. If you have any questions, please contact: PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/pdsd |
||
| 01/10/2024 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-RES-0124-00078 - CE-VIO0423-02812 2808 E ADAMS ST. – R-1 Remodel garage to an accessory dwelling unit (ADU) (1st Review) TRANSMITTAL DATE: January 10, 2024 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in the R-1 zone (UDC 4.7.7). A single family residence with an accessory dwelling unit (ADU) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.6, 8, & 9 and 6.6.3. Provide a residential plot plan that meets the requirements found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Building-Safety/Plan-Examples/Plot-Plan-Example. 1. Clarify why it appears that some of the development on this site is located on the adjacent property to the west. 2. Clarify what you are proposing. The provided floor plan appears to be a sleeping quarters, no kitchen. If this is a sleeping quarters impact fees will not apply. If you are proposing an ADU with cooking facilities clearly demonstrate that the requirements of Unified Development Code (UDC) Article 6.6.3 are met and impact fees will apply. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 01/05/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |