Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Review Status: Requires Resubmit

Review Details: RESIDENTIAL SIMPLE REVIEW v.1

Permit Number - TC-RES-0124-00059
Review Name: RESIDENTIAL SIMPLE REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
01/04/2024 Bldg Permits - Post Review PENDING ASSIGNMENT
01/04/2024 Light Residential Building Review (OIP) REQUIRES RESUBMIT Permit Review TC-RES-0124-00059 (1111 E LIMBERLOST DR Unit:UNIT 183 TUCSON, AZ 85719)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.
Code reference, 2018 International Residential Code (IRC),

1. Clarify if this is a new gas meter where one never existed before, or if this is an existing service that needs to be turned on.
2. Provide a plan set that includes the address and unit number of the meter being turned on.
3. Note and specify all piping materials (Black Iron, Gas line PEX, etc.), G2412.9.
4. Provide the length measured from the meter to the farthest attached appliance. Provide max demand of each appliance. Size the pipe based on the length from the meter to the farthest attached appliance and max total demand of all attached appliances using Table G2413.4(1) (Metallic Pipe), Table G2413.4(7) Polyethylene Plastic Pipe. Note: The length is measured from the meter to the furthest attached appliance for all sizing, G2413.4.1.
5. Yellow tracer wire required for non-metallic pipe, G2415.17.3.
6. Provide a complete gas line schematic, showing all gas connected appliances and pipe sizes. See sample gas template below.

https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/gas_handout_2018_irc_2019.2.4.pdf

https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/sample_gas_template_0.pdf

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov
01/04/2024 PDSD Application Completeness REVIEW COMPLETED