Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.2
Permit Number - TC-RES-0123-02434
Review Name: RESIDENTIAL NEW DWELLING v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/23/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 05/12/2023 | Historic | REQUIRES RESUBMIT | Please include an historic demolition review form, which can be found here. https://www.tucsonaz.gov/files/pdsd/Preservation/Historic_Demolition_Application_Form.pdf | ||
| 05/23/2023 | Residential Building | REQUIRES RESUBMIT | 1. Show the mast height on the electrical riser diagram providing 8’ clearance above the addition roof, E3604.2.1 or relocate the service panel to the south building wall. 2. Protection of all interior 15A & 20A circuits serving outlet locations (except garage, kitchen, and bathrooms) including receptacles, lights and smoke detectors require combination type arc-fault circuit interrupters, E3902.16. Update note #13 by removing "bedrooms" because this is a requirement for the entire dwelling addition. |
||
| 05/15/2023 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: Wyatt Berger Lead Planner PROJECT: TC-RES-0123-02434 2008 E Copper St – R-1 Addition (2nd Review) TRANSMITTAL DATE: May 15, 2023 Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 1. Until all documentation has been submitted, reviewed, and approved by the City Historic Preservation Office, Zoning cannot approve this building plan. Submit the required documentation under activity number TC-RES-0123-02434. If you have any questions about this transmittal, contact me at Wyatt.Berger@tucsonaz.gov or at 520-837-4951. |
||
| 05/01/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |