Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0123-02363
Parcel: 11804135G

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.2

Permit Number - TC-RES-0123-02363
Review Name: RESIDENTIAL NEW DWELLING v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
07/11/2023 Bldg Permits - Post Review Express PENDING ASSIGNMENT
06/15/2023 Residential Building REQUIRES RESUBMIT Provide a complete plan set for review.
05/16/2023 Site Zoning REQUIRES RESUBMIT ZONING REVIEW TRANSMITTAL

FROM: Wyatt Berger
Lead Planner

PROJECT: TC-RES-0123-02363
1648 S San Antonio Dr – R-2
New two-story single-family residence (2nd Review)

TRANSMITTAL DATE: May 16, 2023

Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

The following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1).

2. The Zoning Review Section acknowledges that a Design Development Option (DDO) application has been submitted for TC-RES-0123-02363. Zoning cannot approve this building permit until the DDO process has concluded.

Per UDC 6.3-2.A, when a residential use is adjacent to a residential zone, the required side and rear perimeter yard setbacks are six feet or 2/3 the height of the proposed wall, whichever is greater, measured from the side and rear lot lines.

Based on a wall height of 18’-0”, the required setbacks from the north and south lot lines to the building walls are 12’-0”; proposed is 5’-0”.

Based on a wall height of approximately 9’-7”, the required setbacks from the north and south lot lines to the building walls are approximately 6’-4”; proposed is 5’-0”.

Based on a wall height under 9’-0”, the required setbacks from the north and south lot lines to the building walls are 6’-0”; proposed is 5’-0”.

If you have any questions about this transmittal, contact me at Wyatt.Berger@tucsonaz.gov or at 520-837-4951.
07/11/2023 Zoning Modifications - DDO REQUIRES RESUBMIT FROM: Georgia Pennington, Planner
DATE: 7/11/23

Comments:

1. Resubmit DDO application with correct setback requests.

Please contact me at Georgia.Pennington@tucsonaz.gov or at 520-837-6311 should you have questions about this transmittal.
05/15/2023 PDSD Application Completeness Express REVIEW COMPLETED