Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TC-RES-0123-02155
Parcel: 124070280

Address:
827 E 9TH ST

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.2

Permit Number - TC-RES-0123-02155
Review Name: RESIDENTIAL NEW DWELLING v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
05/04/2023 Bldg Permits - Post Review PENDING ASSIGNMENT
04/14/2023 Site Zoning REQUIRES RESUBMIT ZONING REVIEW TRANSMITTAL

FROM: Wyatt Berger
Lead Planner

PROJECT: TC-RES-0123-02155
827 E 9th St – R-3
Sleeping quarters addition (1st Review)

TRANSMITTAL DATE: April 14, 2023

Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

The following comments may be relative to an application for a Board of Adjustment variance (UDC 3.10.3) or for a Design Development Option (UDC 3.11.1).

1. Zoning acknowledges that a breezeway is proposed to connect the existing principal structure with the existing accessory structure (sleeping quarters). Ensure that the breezeway as depicted on the site plan appears attached to the principal structure.

2. A neighbor’s setback waiver for principal structures cannot be used in accordance with UDC 6.6.2.D. Zoning does acknowledge that the waiver required may be utilized for the relocated 96 sq. ft. storage structure.

Per Tucson Unified Development Code (UDC) Table 6.3-2.A, when a residential use is adjacent to a residential zone, the required side and rear yard setbacks are six feet or 2/3 the height of the proposed wall, whichever is greater, measured from the property line.

Based on an assumed wall height of 11’-2” as measured from design grade to the highest point of the parapet wall, the required side perimeter yard setback is 7’-5” measured from the east property line; the proposed setback is 0’-0” as described on the neighbor’s setback waiver. A Board of Adjustment variance is required to eliminate this setback requirement for both the addition and the breezeway.

An alternative to the Board of Adjustment variance process is a Design Development Option (DDO), which may reduce setbacks for principal structures to no less than 1’-0” from the property line. The DDO application and requirements may be retrieved from: https://www.tucsonaz.gov/files/pdsd/forms/2019_DDO_for_Setback_and_Height_UDC.pdf. The completed application shall be submitted as a PDF under assigned permit number TC-RES-0123-02155. Contact Georgia.Pennington@tucsonaz.gov should you have questions regarding the DDO process.

If you have any questions about this transmittal, contact Wyatt Berger at Wyatt.Berger@tucsonaz.gov or at 520-837-4951.
05/04/2023 Zoning Modifications - Variance REQUIRES RESUBMIT Zoning has identified items that require variances. A Board of Adjustment Variance is processed in accordance with UDC Section 3.10.3. As such, a pre-application meeting and neighborhood meeting is required prior to the submittal of an application. To request a pre-application meeting, please apply for "Pre-Application Conference" at TDC Online. If you have questions, you can email me at Mark.Castro@tucsonaz.gov
03/23/2023 PDSD Application Completeness REVIEW COMPLETED
04/11/2023 Residential Building REVIEW COMPLETED