Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0123-01989
Parcel: 110055070

Review Status: Requires Resubmit

Review Details: COMMERCIAL PDSD SIMPLE REVIEW v.3

Permit Number - TC-RES-0123-01989
Review Name: COMMERCIAL PDSD SIMPLE REVIEW v.3
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
03/18/2023 Bldg Permits - Post Review Express PENDING ASSIGNMENT
03/20/2023 Light Residential Building Review (OIP) REQUIRES RESUBMIT Permit Review TC-RES-0123-01989 (2815 N ORLANDO AV TUCSON, AZ 85712)

Provided spec sheet indicates ¾” connection to the Heater can only be 18”-24” long. Gas Permit file shows ¾” pipe at 6’. 1 ¼” pipe must run the complete distance to the furnace as indicated in the Pool Heater spec sheet.

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov
03/18/2023 PDSD Application Completeness Express REVIEW COMPLETED