Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0123-01934
Parcel: 138210900

Address:
201 W TETON ST

Review Status: Approved

Review Details: RESIDENTIAL SOLAR v.1

Permit Number - TC-RES-0123-01934
Review Name: RESIDENTIAL SOLAR v.1
Review Status: Approved
Review Date Reviewer's Name Type of Review Description Status Comments
01/14/2023 External Reviewers - SAFEBuilt APPROVED Activity Number: TC-RES-0123-01934

GENERAL:
Provide written responses to all review comments.
Provide a complete plan set.
Provide additional documents as requested by review staff.


STRUCTURAL REVIEW COMMENTS:
Conditionally Approved
Solar panel mounting and anchorage to be as described in the licensed engineer’s structural analysis. Staggered mounting required. Maximum panel support spacing no greater than 6 ft. on center. Provide minimum anchorage (2) 1/4 inch diameter lag screws with a minimum 2-1/2 inch embedment at each connection.


BUILDING REVIEW COMMENTS:
Conditinally Approved
Addition to existing system.
Roof penetrations shall be flashed in accordance with IRC R324.4.3


MECHANICAL REVIEW COMMENTS:
N/A


ELECTRICAL REVIEW COMMENTS
Approved


PLUMBING REVIEW COMMENTS:
N/A


If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov
01/25/2023 Light Residential Building Review (OIP) APPROVED
01/26/2023 Bldg Permits - Post Review Express REVIEW COMPLETED
01/06/2023 PDSD Application Completeness Express REVIEW COMPLETED