Permit Number: TC-MDP-1225-00764
Parcel: 12417085A

Review Status: In Review

Review Details: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1

Permit Number - TC-MDP-1225-00764
Review Name: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1
Review Status: In Review
Review Date Reviewer's Name Type of Review Description Status Comments
12/23/2025 Residential Building APPROVED
12/19/2025 Residential Engineering APPROVED
12/17/2025 Fire New Construction NOT REQUIRED
N/A Bldg Permits - Post Review Express PENDING ASSIGNMENT
N/A ROW Engineering Review PENDING ASSIGNMENT
12/24/2025 Residential Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Roxanne Johnston
Planner

PROJECT: TC-MDP-1225-00764
1030 S Fremont Av Unit 1., Tucson, AZ 85719
Model Duplex (1st Review)

TRANSMITTAL DATE: 12/24/2025

This site is located within the R-2 Zone (UDC 4.7.9). A duplex is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6, .9, & .10.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed.

1. A 6’ side perimeter setback is proposed on south side of the property line and 6.51’ & 6.52’ on the north side as shown on the site plan (Sheet 1 of 1). The associated duplex model, TC-MDP-1025-00684 (Sheet A3) illustrates a wall height up to 23’-9”. Per UDC 6.4.4.A., building height is the vertical distance measured from the design grade elevation to the highest point of a flat roof; to the deck line of a mansard roof; or to the middle (between the eave and ridge) of the highest gable of a pitched or hipped roof. The model plan does not indicate a design grade measurement. Revise the plans to reflect measurements from design grade.

2. A note on Sheet 1 of 1 indicates that a Design Development Option (DDO) will be submitted for a reduced setback. Site Zoning is unable to approve the site plan until the DDO has been approved. The application needs to include all amended exterior wall heights, particularly the 23’-9” and 8’-6” walls as amended. To submit an application for a DDO, please use the link and follow the instructions below:
www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/boards-committees commissions/drb/012425/ddo-24-81-application-packet.pdf Submit a DDO application under the Zoning Modification sub-record that you will create - for instructions on how to apply for a sub-record, visit the following link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/new-pdfs/sub-records_071425.pdf
For questions regarding the DDO process, please contact Georgia Pennington at georgia.pennington@tucsonaz.gov

3. The site plan contains a Line Table and Site Zoning staff acknowledge receipt of the lot’s Warranty Deed. Please ensure the correct legal lot description is added to the site plan.

4. Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted for the next review.

If you have any questions about this transmittal, please contact Roxanne Johnston at roxanne.johnston@tucsonaz.gov .
12/16/2025 PDSD Application Completeness Express REVIEW COMPLETED
12/23/2025 TW New Development Review Fast REVIEW COMPLETED Based on the information provided, Tucson Water’s New Area Development (NAD) has no objections to the proposed development. However, based on the fixture counts provided and per the IPC, the existing 5/8" meter must be upsized to a 3/4" meter.

If any new domestic water services are needed to serve this proposed development, please contact Tucson Water’s New Services Section at 520-791-5164 or via email at TW_Common@tucsonaz.gov
.

These comments are based on the limited preliminary information provided by the applicant.