Permit Review Detail
Review Status: Requires Resubmit
Review Details: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1
Permit Number - TC-MDP-1223-01878
Review Name: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/19/2023 | Site Engineering | APPROVED | |||
| 12/19/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 12/06/2023 | Residential Building | REQUIRES RESUBMIT | Permit Review TC-MDP-1223-01878 (236 E 25TH ST TUCSON, AZ 85713) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Residential Code (IRC). 1. There doesn’t appear to be a Pima County sewer line to the north of this property. Verify the location of the PC sewer line and show this line on the site plan. Show connection from the clean outs to the PC sewer line. 2. Provide elevation measurements for Next Upstream Manhole and Finished Floor Elevation. Provide Backwater valve protection as/if required. Backwater valve protection: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/building-code/2018_-_irc_amendments.pdf Section P3008.1. 3. The OHE line is shown passing over a neighboring property. Show the location of the neighboring structures to show compliance with OHE clearance above a structure, E3604.2.1. a. Provide 8’ clearance above the structure’s roof for a minimum distance of 3’ on all sides or relocate the service entrance or OHE to a code compliant location, E3604.2.1. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 12/06/2023 | ROW Engineering Review | REQUIRES RESUBMIT | Site plan: Show existing and proposed Right-of-Way features; see plot plan example. Provide distances and dimensions for the following: 1. Driveway 2. Curb and curb cuts 3. Sidewalk *New construction in the public Right-of-Way shall be in conformance with the current edition of Pima Association of Governments (PAG) Standard Specifications and Details for public improvements. Visit https://apps.pagregion.com/standardspecifications/ for more information. Chapter 25-38 residential driveway layout and PAG Standard Detail 206 have been added in attachments. |
||
| 12/19/2023 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-MDP-1223-07878 236 E 25th St. Tucson, AZ. 85713 New Duplex (1st Review) TRANSMITTAL DATE: December 19, 2023 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in the R-2 zone (UDC 4.7.9). A duplex is a permitted use in this zone (UDC Table 4.8-2), with Use Specific Standards UDC Article 4.9.7.B.6,.9, & 10. 1. Provide a dimension from the center line of 25th St to the face of curb and from the face of curb to the north property line. If you have any questions about this transmittal, please contact Nathan Herrera at Nathan.Herrera@tucsonaz.gov |
||
| 12/11/2023 | Fire New Construction | REVIEW COMPLETED | |||
| 12/06/2023 | PDSD Application Completeness Express | REVIEW COMPLETED | Addressing condition added for Unit 1 and Unit 2 needing to be added to the address. Please contact Pima County Addressing to resolve issue. Addressing@pima.gov or 520-724-9512 |