Permit Number: TC-MDP-1223-01855
Parcel: 125091400

Address:
2904 E 10TH ST

Review Status: Requires Resubmit

Review Details: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1

Permit Number - TC-MDP-1223-01855
Review Name: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
12/19/2023 Site Engineering APPROVED
12/05/2023 ROW Engineering Review NOT REQUIRED
12/19/2023 Bldg Permits - Post Review PENDING ASSIGNMENT
12/06/2023 Residential Building REQUIRES RESUBMIT Permit Review TC-MDP-1223-01855 (2904 E 10TH ST TUCSON, AZ 85716)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.
Code reference, 2018 International Residential Code (IRC).

1. Provide electrical load calculations for the Existing Dwelling Unit’s service panel, for determining the service panel size, E3602.2. Show the main panel size. Show the main panel is sized to for the additional ADU load.
2. Notate and specify all piping materials and sizes, for the existing HCS pipe. Show existing HCS is sized in compliance with P3005.4.
3. Provide elevation measurements for Next Upstream Manhole (Structure ID: 8178-55) and Finished Floor Elevation. Provide Backwater valve protection as/if required.
Backwater valve protection:
https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/building-code/2018_-_irc_amendments.pdf Section P3008.1.
4. Provide a complete fixture unit schedule for the ADU, P2903.6. Provide the water pipe diameter between the meter and shut off valve in compliance with P2903.7. A minimum 1” service pipe is usually required for supplying water to more than 9.5 fixture units.
5. Provide a complete fixture unit schedule for the Existing Dwelling Unit, P2903.6. Provide the water pipe diameter between the meter and the junction feeding the ADU and Existing Dwelling Unit, in compliance with P2903.7.

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov
12/05/2023 Site Zoning REQUIRES RESUBMIT FROM: PDSD Zoning Review Section

PROJECT: TC-MDP-1223-01855
2904 E 10TH ST. – R-1
New ADU (1st Review)

TRANSMITTAL DATE: December 5, 2023

COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This site is located in the R-1 zone (UDC 4.7.7). A single family residence with an accessory dwelling unit (ADU) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.6, 8, & 9 and 6.6.3.

1. Per UDC Article 6.4.4.A Measurement of Building Height, building height is the vertical distance measured from the design grade elevation to the middle (between the eave and ridge ) of the highest gable of a pitched or hipped roof, except as follows: (See Figure 6.4.4-A, Measurement of Building Height.) As the distance from design grade to the midpoint of the roof was not provided on the elevations provided in the model plan of the proposed ADU Zoning can determine if the ADU meets building height requirements. Provide an elevation of the proposed ADU with a dimension from design grade to the midpoint of the pitched roof.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
12/11/2023 Fire New Construction REVIEW COMPLETED
12/05/2023 PDSD Application Completeness REVIEW COMPLETED